SL24.W
Number of self-reset counter
Reading of the number of control
panel self-resets
A self-reset is a reset of the microswitch
by the control panel for safety reasons.
RSTC
Typically the control panel goes to self-reset
when the minimum microswitch voltage
threshold has been reached. An excessive
number of self-resets could indicate a poor
quality power supply, subject to strong volt-
age fluctuation.
Reset number of self-reset
counter
RSTE
Waiting press OK for 5 s to reset
the counter to 0
Installer telephone settings and
display
Press OK briefly to view the
saved number (use buttons ▲▼
to scroll)
First 4 digits of the installer number
Next 4 digits of the installer
TL
number
Last 2 digits of the installer number
In the example shown above the installer
telephone number is: 333 4254832
Press OK for 5 s to enter the number edit
mode. Use buttons ▲▼ to change the
value, use OK to confirm the digit
Control panel info display
INF
Control panel name
Control panel firmware version
Connection module
Sub
Description
menu
Connection module on CNX1
connector
CNX1
No module connected
Wi-Fi module EMC.W connected
Connection module on CNX2
connector
No module connected
Opposing leaf module EMX.W
CNX2
connected. Control panel function-
ing as MASTER
Opposing leaf module EMX.W
connected. Control panel function-
ing as SLAVE
22
Restore default values and loading from memory
card
1123
Sub
Description
menu
Loading the default values
Waiting press OK for 5 s to load
the default values.
Note:
DEF
Loading the default values then requires the
travel to be calibrated again, LRNT flashes
on the display until (rapid or advanced)
calibration is done.
Loading the programming from
memory card
oooo
Waiting press OK for 5 s to load
the values from memory card.
MEM
Loading from memory card com-
pleted OK.
Loading from memory card error
(e.g. no card).
Control panel protection level settings
3334
(default = OFF)
2548
OFF No protection
Protection of menus MOT, LRNT, TRV, OUT,
32
1
IN, LGC, STAT, EXP, LOAD
2
Protection of menu RAD
Protection from IP connection (it is not pos-
3
sible to connect to the control panel from a
smartphone)
Protection of menus MOT, LRNT, TRV,
4
OUT, IN, LGC, STAT, EXP, LOAD and IP
SL24.W
connection
1.13
5
Protection of menu RAD and IP connection
6
Complete control panel protection
Values
Protection of all board menus, IP connection
(default)
7
available
(1)
OFF
1
(OFF)
OFF
1
2
EN
Msg
display
oooo
oooo
DONE
EMEM