Remote programming of remote
controls (default = 1)
Remote programming of remote
controls off
Remote Programming of
remote controls on: used to
programme remote controls
from a remote control
already in the memory
using the following procedure:
- press buttons 1 and 2 on the
remote control already in the
memory at the same time
RE
- press the button on the remote
control already in the memory to
copy on the new remote control
- press the button on the new
remote control on which to copy
the button just pressed on the
remote control already in the
memory.
Note: the button on the new
remote control just saved inherits
the function assigned to the but-
ton on the remote control already
in the memory
Total receiver memory deletion
Press OK for 5 s
ERSA
Signals the deletion of the receiver
memory on the display
Deletion of single remote control
from its position in the memory
Use buttons ▲▼ to select the
ERS1
number of the remote control to
delete
Press OK to confirm
Deletion of single remote control
from the remote control code
ERSR
Waiting for code
Deleting remote control
Diagnostics and reporting
Sub
Description
menu
Alarm log reading
Most recent alarm
ALM
Oldest alarm
Error signalling (default = 1)
Only on display
ALMA
On display and maintenance
output
Reading of number of manoeu-
vres since last maintenance
First 3 digits of the number of ma-
noeuvres since last maintenance
Last 3 digits of the number of ma-
MNPC
noeuvres since last maintenance
In the case described above, the gate has
carried out 23,256 manoeuvres since the
last maintenance
Number of manoeuvres since
last maintenance
Number of manoeuvres generat-
OFF
ing a maintenance signal (in thou-
sands of manoeuvres) (default
= OFF)
MNPS
Maintenance signalling off
1,000 manoeuvres (minimum
interval)
300,000 manoeuvres (maximum
interval)
Maintenance signalling
(default = 1)
Signalling only on display
Signalling on display and mainte-
nance output (MAN)
1
Signalling on display and flashing
MNPA
light (rapid flashing at end of
manoeuvre)
Signalling on display, flashing
light (rapid flashing at end of
manoeuvre) and maintenance
output (MAN)
Reset manoeuvres since last
maintenance counter
MNPE
Waiting press OK for 5 s to reset
the counter to 0
Total manoeuvres counter
First 4 digits of the number of ma-
noeuvres since last maintenance
MNTC
Last 4 digits of the number of ma-
oooo
noeuvres since last maintenance
In the case described above, the gate has
carried out 125,874 manoeuvres in total
Life counter (days of activity of
the control panel)
X
Reading of the number of days of
LIFE
activity of the control panel
In the case described above, the control
panel was active for 584 days
Number of control panel power-
oooo
ups counter
Reading of the number of control
panel power-ups
Msg
PONC
In the example shown above, the control
display
panel was powered up 2547 times (it could
indicate a poor quality mains electricity, with
0
frequent power cuts)
10
Reset number of control panel
power-ups counter
1
PONE
Waiting press OK for 5 s to reset
2
the counter to 0