Télécharger Imprimer la page

Vimar SL24.W Guide Rapide Installateur page 17

Masquer les pouces Voir aussi pour SL24.W:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
SL24.W
All sub-menus are described in the following table:
Motor parameters
Sub
Description
menu
Type of actuator used
Warning! If set to OFF
the board performs no
O1
command !
Not set
Acto 600D (ESM2)
Acto 1000D (ESM2.1000)
Type of position control
Automatically set with the choice
of actuator. You are advised not
to change the setting given by the
type of actuator.
O2
Virtual encoder: the control
panel calculates the gate position
using the electric motor operating
parameters
Encoder for Acto 600D (ESM2)
Type of limit switch on opening
Automatically set with the choice
of actuator. You are advised not
to change the setting given by the
type of actuator.
No limit switches on opening:
the electric motor stops at the end
O3
of the working time
Stop limit switch on opening:
the limit switch stops the motor
Limit switch in proximity open-
ing: the limit switch allows the
manoeuvre to continue at the
approach speed set until it detects
the mechanical stop
Type of limit switch on closing
Automatically set with the choice
of actuator. You are advised not
to change the setting given by the
type of actuator.
No limit switches on closing:
the electric motor stops at the end
O4
of the working time
Stop limit switch on closing: the
limit switch stops the motor
Limit switch in proximity clos-
ing: the limit switch allows the
manoeuvre to continue at the
approach speed set until it detects
the mechanical stop
Note:
O2, O3, O4 are automatically set with the choice of actua-
tor. You are advised not to change the setting given by the
type of actuator.
Motor travel calibration procedure
Rapid travel calibration.
The calibration is done fully automatically
Values
and sets:
(default)
- The slowdown in opening at 20% of the
(1)
- The slowdown in closing at 20% of the total
- Pedestrian opening at 30% of the total travel
OFF
Button
1
2
-
LRNE
PP
(3)
-
2
-
3
-
-
(1)
-
Advanced travel calibration.
The calibration allows the installer to choose:
OFF
- Slowdown position in opening
- Slowdown position in closing
1
- Pedestrian opening position
Button
-
2
PP
(1)
PP
OFF
LRNA
-
1
PP
2
-
PP
EN
total travel
travel
Msg on
Phase description
display
PP
Wait for start of cali-
bration procedure
CL 1
When button
pressed: closing and
search for closing
limit switch
OP 1
Opening travel meas-
urement
CL 1
Closing travel meas-
urement
OPC1
Opening current
curve reading
CLC1
Closing current curve
reading
END
End of procedure
Msg on
Phase description
display
PP
Wait for start of cali-
bration procedure
CL 1
When button
pressed: closing and
search for closing
limit switch
OP 1
Start opening. When
button pressed: slow-
down start position
on opening setting
OP 1
Continuation of open-
ing and slowdown
speed up to opening
limit switch
CL 1
Start closing. When
button pressed: slow-
down start position
on closing setting
CL 1
Continuation of
closing at slowdown
speed up to closing
limit switch
OPED
Start pedestrian
opening. When but-
ton pressed: pedes-
trian opening position
setting
15

Publicité

loading

Ce manuel est également adapté pour:

Elvox sl24.w