Télécharger Imprimer la page

Vimar SL24.W Guide Rapide Installateur page 22

Masquer les pouces Voir aussi pour SL24.W:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
SL24.W
Clearance time (adjustable at
intervals of 1 s)
Time after which the gate closes
L7
again if the rapid closing (L6) is on
Minimum clearance time
Maximum clearance time
Pre-flash
Flashing time of the flashing light
before the gate starts to move
L8
Pre-flash disabled
3 s pre-flash
4 s pre-flash
5 s pre-flash
Manned
Manned function off
Step-step command disabled,
remote controls not working. The
control panel accepts only open
L9
and close commands
Emergency manned. In normal
standard operating conditions,
with the safety devices occupied it
works as manned.
Step by step
Step-step command operates in
2 steps:
open, close, open...
Step-step command operates in
L10
3 steps:
open, stop, close, open...
Step-step command operates in
4 steps:
open, stop, close, stop, open...
Stop from step-step
Automatic closing disabled when
a stop command from step-step
L11
is given
Automatic closing not disabled
when a stop command from step-
step is given
Stop from stop
Automatic closing disabled when a
stop command from stop is given
L12
Automatic closing not disabled
when a stop command from stop
is given
Operation in battery
Standard operation
Normal operation with flashing
light disabled
L14
After a re-open command it stays
open
When the main power supply is
cut off it opens and remains open
Economy
Standard operation
Economy operation on. With the
L15
gate closed, it switches off the
accessory power supply on outputs
1 and 2. The outputs are powered
again following a new command.
20
Gate remained open indicator
Number of minutes after which,
(2)
with the gate partially or totally
open, whatever the set pause
1
time, an alarm signal is sent (on
L16
the display and output configured
10
as OAB)
Indicator disabled
(OFF)
Minimum interval
OFF
Maximum interval
3
Remote control management
4
Sub
Description
5
menu
(OFF)
Saving a button as step-step
OFF
Waiting for code
Remote control 1 saved as step-
PP
step
1
Remote control 55 saved as
step-step
Saving a button as open
Waiting for code
2
OPEN
Remote control 1 saved as open
Remote control 55 saved as open
Saving a button as pedestrian
(4)
Waiting for code
Remote control 1 saved as
2
PED
pedestrian
Remote control 55 saved as
pedestrian
3
Saving a button as
Auxiliary Radio Output activa-
tion
4
Waiting for code
RAU
Remote control 1 saved as Auxil-
(ON)
iary Radio Output
Remote control 55 saved as Auxil-
OFF
iary Radio Output
Saving a button as close
Waiting for code
ON
CLS
Remote control 1 saved as close
Remote control 55 saved as close
(ON)
Saving a button as stop
OFF
Waiting for code
STP
Remote control 1 saved as stop
Remote control 55 saved as stop
ON
Saving a button as
Courtesy Light on
(1)
Waiting for code
1
Remote control 1 saved as Cour-
LCO
2
tesy light on
Remote control 55 saved as Cour-
3
tesy light on
Control of remote control
4
memory position
Waiting for code
(OFF)
Remote control button 1 saved
OFF
as close
CTRL
Remote control button 99 saved
as Courtesy light on
1
Remote control button 30 not in
memory
Remote control not in memory
EN
(30)
OFF
3
60
Msg
display
oooo
1001
1055
oooo
2001
2055
oooo
3001
3055
oooo
4001
4055
oooo
5001
5055
oooo
6001
6055
oooo
7001
7055
oooo
5001
7099
-030
----

Publicité

loading

Ce manuel est également adapté pour:

Elvox sl24.w