SL24.W
Normal motor speed when
opening
T24
minimum speed
maximum speed
Normal motor speed when
closing
T26
minimum speed
maximum speed
Motor slowdown speed when
opening
T28
minimum speed
maximum speed
Motor slowdown speed when
closing
T30
minimum speed
maximum speed
Motor slowdown distance when
opening
% of travel or total work time done
T32
at slowdown speed
No slowdown
Slowdown for the whole distance
Motor slowdown distance when
closing
% of travel or total work time done
T34
at slowdown speed
No slowdown
Slowdown for the whole distance
Motor acceleration time when
opening
Time during which the motor
accelerates to reach the normal
opening speed (adjustable at inter-
T36
vals of 0.1 s)
Maximum acceleration (0 s to
reach normal speed)
Minimum acceleration (2.0 s to
reach normal speed)
Motor acceleration time when
closing
Time during which the motor ac-
T38
celerates to reach the normal clos-
ing speed (adjustable at intervals
of 0.1 s)
Maximum acceleration (0 s to
reach normal speed)
T38
Minimum acceleration (2.0 s to
reach normal speed)
Motor deceleration ramp
Deceleration ramp between nor-
mal motor speed and slowdown
T40
speed
Steep ramp (maximum deceleration)
Low ramp (minimum deceleration)
Auxiliary output configuration
90
Sub
Description
1
menu
Terminal A1 output type
100
Output off
90
Gate open warning light (SCA)
Operation as per SCA parameter
1
setting
100
Auxiliary Radio output (RAU)
Operation as per RAU parameter
30
setting
1
Courtesy light (LCO)
100
On during leaf movement and for
the amount of time after the leaf
(30)
A1
stopping set in parameter LCO
1
Zone light (LZO)
On during leaf movement
100
Gate left open (OAB)
On if the gate remains open for a
(20)
time longer than that defined by
the open gate alarm logic (L16)
Maintenance (MAN)
0
Output off when the number of
100
maintenance signalling manoeu-
vres (MNPS) is reached in the
(20)
diagnostics section
Terminal A2 output type
Output off
0
Gate open warning light (SCA)
100
Operation as per SCA parameter
setting
Auxiliary Radio output (RAU)
Operation as per RAU parameter
(0.5)
setting
Courtesy light (LCO)
On during leaf movement and for
the amount of time after the leaf
0
A2
stopping set in parameter LCO
Zone light (LZO)
2.0
On during leaf movement
Gate left open (OAB)
On if the gate remains open for a
time longer than that defined by
(0.5)
the open gate alarm logic (L16)
Maintenance (MAN)
Output off when the number of
maintenance signalling manoeu-
0
vres (MNPS) is reached in the
diagnostics section
2.0
(30)
0
100
EN
Values
(default)
(1)
OFF
1
2
3
4
5
6
(2)
OFF
1
2
3
4
5
6
17