INSTALLATION
Remove the appliance from the package and check that the product and power cord are NOT damaged.
Otherwise, contact the retailer before operating the appliance.
Do not lift the product by the door handle.
Packaging (e.g. paper, polystyrene) may be hazardous to children (danger of suffocation).
Keep packaging out of the reach of children.
The product must be installed and connected correctly to the mains power supply, following the
manufacturer's instructions and only by QUALIFIED PERSONNEL.
Before performing any type of work, it must be verified that the appliance is DISCONNECTED from the mains
power supply.
Connection to the mains power supply
Make sure the voltage matches that indicated on the type plate which can be viewed by opening the oven
door.
Check whether there is an omnipolar switch available on the domestic line which is compliant with current
standards (3 mm minimum opening distance between contacts) and if it is able to support the load of the
appliance (see the type plate). Otherwise place a device, easily reachable, between the appliance and the
electricity line with the described specifications.
CAUTION: Check whether your electrical system is equipped with an efficient earth connection according to
current standards and legal provisions.
N.B. The earth connection is required by law.
The yellow/green earth cable must not be interrupted by the switch and must be 2-3 cm longer than the other
cables.
Do not position the power cord near sources of heat or at temperatures more than 50°C above the room
temperature.
If the appliance is lacking the power cord, the oven must be connected to the mains power supply with a cable
having a minimum section of 1.5mm².
If a plug is to be used, it must be a standard plug suitable for the load and the power outlet.
Replacement of the power cord:
If the power cord needs to be replaced, use cables of the following type only:
H05 RR-F, H05V2V2-F(T-90)
Wire sections 3x1.5mm²
Terminal box
The oven is equipped with a terminal box set up for operation with a single-phase 220-240V~ 50Hz supply
voltage.
Attention:
should it be necessary to replace the supply cord, connect the wire in accordance with the following
colours/codes:
BLUE
BROWN
YELLOW-GREEN
- NEUTRAL (N)
- LIVE (L)
- EARTH (
)
8