General Outline; General Safety - BFT MICHELANGELO Instructions D'utilisation Et D'installation

Masquer les pouces Voir aussi pour MICHELANGELO:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
Thank you for buying this product. Our Company is sure that you will be
more than satisfied with the performance of the product. This product is
supplied with a "WARNINGS" leaflet and an "INSTRUCTION MANUAL".
These should both be read carefully as they provide important informa-
tion about safety, installation, operation and maintenance. This product
complies with recognised technical standards and safety regulations. We
declare that this product is in conformity with the following European Direc-
tives: 89/336/CEE, 73/23/EEC, 98/37/EEC, 99/05/EEC and subsequent
amendments.

1) GENERAL OUTLINE

Compact electromechanical barrier suitable for limiting private areas,
parkings, access areas for vehicles only. Available for passageways from
6 to 8 metres. Adjustable electronic limit switches, they guarantee cor-
rect boom stopping position. In case of intensive use, a thermal sensor
activates the cooling fan.
The emergency release device for manual manoeuvre is controlled by a
personalised key lock.
The actuator is always supplied for left-hand side fitting. However, when
necessary, the opening direction can be reversed by means of simple
operations.
The BM mod. foundation base (on request) makes barrier installation
easier.
Appropriate fittings make it easy to install accessories.
The LIBRA C MV control panel is supplied by the manufacturer with stan-
dard setting. Any change must be set by means of the incorporated display
or by means of the universal programmer. The Control unit completely
supports the EELINK protocol, including the programmer self-supply from
the control unit.
Its main characteristics are:
- Electronic speed adjustment with slow-down at the end of run.
- Inputs for mechanical position reference elements.
- Separate inputs for safety devices
- Clock input (TIMER)
- Serial protocol connection input
- Incorporated rolling-code radio receiver with transmitter cloning.
The board is provided with a terminal board which can be pulled out for
easier maintenance or replacement. The board is supplied with a series
of pre-wired jumpers to facilitate the installer's work.
The jumpers relate to the following terminals: 15-17, 15-18, 15-20. If the
above-mentioned terminals are in use, remove their respective jumpers.

2) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
• The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
• Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
• Keep the instructions together with the technical brochure for future
reference.
• This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
• The Company declines all responsibility for any consequences result-
ing from improper use of the product, or use which is different from that
expected and specified in the present documentation.
• Do not install the product in explosive atmosphere.
• The construction components of this product must comply with the
following European Directives: 89/336/EEC, 73/23/EEC, 98/37/EEC,
99/05/EEC and subsequent amendments. As for all non-EEC countries,
the above-mentioned standards as well as the current national standards
should be respected in order to achieve a good safety level.
• The Company declines all responsibility for any consequences result-
ing from failure to observe Good Technical Practice when constructing
closing structures (door, gates etc.), as well as from any deformation
which might occur during use.
• The installation must comply with the provisions set out by the following
European Directives: 89/336/EEC, 73/23/EEC, 98/37/EEC, 99/05/EEC
and subsequent amendments.
• Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
• Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
• Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
INSTALLATION MANUAL
• Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with
an earth terminal.
• Fit all the safety devices (photocells, electric edges etc.) which are
needed to protect the area from any danger caused by squashing,
conveying and shearing, according to and in compliance with the ap-
plicable directives and technical standards.
• Position at least one luminous signal indication device (blinker) where
it can be easily seen, and fix a Warning sign to the structure.
• The Company declines all responsibility with respect to the automation safety
and correct operation when other manufacturer's components are used.
• Only use original parts for any maintenance or repair operation.
• Do not modify the automation components, unless explicitly authorised
by the Company.
• Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
• Do not allow persons or children to remain in the automation operation
area.
• Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
• The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
personnel.
• Anything which is not expressly provided for in the present instructions,
is not allowed.
• Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.
3) TECHNICAL SPECIFICATIONS
MICHELANGELO
Power supply: .............................................................230V±10% 50Hz(*)
Power absorbed: ............................................................................. 300W
Motor: ....................................................................................... 1600 min
Absorption: .......................................................................................... 1 A
Internal lubrication: ...................................................... permanent grease
Max torque: ................................................................................... 600 Nm
Opening time: ................................................................. 6s (6m), 8s (8m)
Boom length: .................................................. 6m (MICHELANGELO 60)
......................................................from 6m to 8m (MICHELANGELO 80)
Impact reaction: ............................................................................encoder
Manual mechanical release: ............................................. customised key
Type of boom: ............................................................... rectangular/round
Limit devices: ........... electrical incorporated and electronically adjustable
Maximum no. manoeuvres in 2h: ........................... continuous operation
Working temperature: ............................................... from -10°C to +55°C
Degree of protection: ........................................................................ IP 2
Operator weight (without boom): ................58 Kg (MICHELANGELO 60)
....................................................................68 Kg (MICHELANGELO 80)
Dimensions: ................................................................................. see fig.1
(*)= special power supply voltages on request.
4) FOUNDATION PLATE (Fig.2)
-
Prepare a foundation hole suitable for the particular kind of ground.
-
Layout several raceways for the electric cables to pass through.
-
Position the screws supplied with the barrier pack into the  fixing holes
with the thread facing upwards. Weld the  screw heads to the base
and protect the welds with rust preventer. Position the base so that it
protrudes about 20mm from the floor (fig.2).
-
Fill the hole with concrete, checking the position of the base in both
directions by means of a level, and let the cement harden.
5) FITTING OF THE ACTUATOR
WARNING! The barrier must be exclusively used for vehicles to
drive through. Pedestrians must not walk within the operator
manoeuvring area. An appropriate pedestrian passageway must be
provided for.
The passageway must be suitably indicated by means of the warning
signs illustrated in Fig.8.
WARNING: before opening the door, the spring must be unloaded
(vertical boom). The door of the box must be facing towards the inside
of the property. When you stand in the middle of the passageway, facing
outwards, if the box is on your left, the barrier is left-hand fitted, if the box
is on your right, the barrier is right-hand fitted.
The actuator is always supplied for left-hand side fitting.
5.1) Left-hand fitting
-
Fix the operator to the foundation base and secure it by means of nuts
M12. The door of the box must be facing towards the inside of the
property.
ENGLISH
-1
13
MICHELANGELO -

Publicité

Table des Matières
loading

Table des Matières