General Outline; General Safety - BFT MOOVI 30-50 Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
Thank you for buying this product. Our company is sure that you will be
more than satisfied with the performance of the product. This product is
supplied with a "WARNINGS" leaflet and an "INSTRUCTION MANUAL".
These should both be read carefully as they provide important information
about safety, installation, operation and maintenance. This product complies
with recognised technical standards and safety regulations. We declare
that this product is in conformity with the following European Directives: 89/
336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments.

1) GENERAL OUTLINE

Compact electromechanical barrier suitable for limiting private areas,
parkings, access areas for vehicles only. Available for passageways from
3 to 5 metres. Adjustable electromechanical limit devices ensuring a correct
stop position for the boom. In case of intensive use, a thermal sensor
activates the cooling fan.
The emergency release device for manual manoeuvre is controlled by a
personalised key lock.
The actuator is always supplied for left-hand side fitting.However, when
necessary, the opening direction can be reversed by means of simple
operations.
The CBO mod. foundation base (on request) makes barrier installation
easier.
Appropriate fittings make it easy to install accessories without needing to
drill any holes.

2) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this product
should be read carefully as they provide important information about
safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in this
documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments. As for all non-EEC countries, the above-mentioned standards
as well as the current national standards should be respected in order to
achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing, according to and in compliance with the applicable directives
and technical standards.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components are
used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised by
the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation
INSTALLATION MANUAL
operation area.
Keep radio control or other control devices out of children's reach, in order
to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
personnel.
Anything which is not expressly provided for in the present instructions, is
not allowed.
3) TECHNICAL SPECIFICATIONS
MOOVI 30-50
Power supply: ....................................................... 230Va.c.±10% 50Hz (*)
Absorbed power: ...............................................................................300W
Motor: ........................................................................... 1400 min
Capacitor: ....................................... 8µF 450V (230V) :32µF 250V (110V)
Absorption: .............................................................................. 0.8 A :1.6 A
Insulation class: ........................................................................................ F
Ventilation intervention temperature: ............................... 110°C (winding)
Circuit-breaker intervention temperature: ............... 130°C (self-resetting)
Reduction gear lubrication: .......................................... Permanent grease
Max torque: .................................... MOOVI-30 85Nm: MOOVI-50 250Nm
Opening time: ............................................. MOOVI-30 4s : MOOVI-50 8s
(Aluminium) bar length: ........... MOOVI-30 3m max : MOOVI-50 5m max.
Impact reaction (electric edge): .......................... Stop or stop and reverse
Limiting devices: ............................. Electric, incorporated and adjustable
Manual manoeuvre: ....................................................... Quick key release
No. manoeuvres in 24 hour: ............. 1200 (MOOVI-30) :600 (MOOVI-50)
Working temperature: ......................................................... -10°C ÷ +55°C
Degree of protection: ...........................................................................IP24
Actuator weight (without bar): .......................................... 356N (~35.6 kg)
Dimensions: .................................................................................. See fig.1
MIZAR BOM CONTROL PANEL
Power supply: ....................................................... 230Va.c.±10% 50Hz (*)
Loadless absorption: .................................................................... 100 mA
Accessory output power: .......................................... 24Va.c. 200 mA max
Max. motor power absorbed: ........................................................... 500W
Limits switch: ....................................................................... electric switch
Working time: ....................................................... adjustable from 1 to 30s
Working temperature: ............................................................... -10 +55 °C
(*) Special power voltages available on request.
4) OPTIONAL ACCESSORIES (Fig.17)
-
CBO. Foundation base
-
MOOVI PRM. Antishearing Kit
-
MOOVI 130. Kit for Cellula 130 fixing post
-
FAF. Fixed fork for boom rest
-
MOOVI GA. Movable rod for boom rest (Only for MOOVI 50)
-
MOOVI GAMA. Movable cushioned rod for boom rest
-
SB. Skirt already assembled to the boom
-
Safety edge BIR
-
MOOVI LIGHT. Light kit for booms from 3m to 4.5m
-
MOOVI LIGHT 1. Light kit for booms from 5m to 6m
-
MOOVI PCA. Lower or upper boom covering contour
For further information about installation and use of the accessories, make
reference to their respective instruction manuals.
5) FOUNDATION PLATE (Fig.2)
-
Prepare a foundation hole suitable for the particular kind of ground.
-
Layout several raceways for the electric cables to pass through.
-
Position the screws supplied with the CBO mod. base into the 4 fixing
holes with the thread facing upwards. Weld the 4 screw heads to the base
and protect the welds with rust preventer. Position the base so that it
protrudes about 20mm from the floor (fig.2).
-
Fill the hole with concrete, checking the position of the base in both directions
by means of a level, and let the cement harden.
6) FITTING OF THE ACTUATOR
WARNING! The barrier must be exclusively used for vehicles to
drive through. Pedestrians must not walk within the operator
manoeuvring area. An appropriate pedestrian passageway must be
provided for.
The passageway must be suitably indicated by means of the warning
signs illustrated in Fig.10.
WARNING: before opening the door, make sure that the spring has
been unloaded (rod at 43
the property. When standing in the middle of the passageway, if the box is
on the left the barrier opens to the left, and if the box is on the right the barrier
ENGLISH
°
). The door of the box must face the inside of
MOOVI 30-50 Ver. 04 -
-1
, 4 poles
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Moovi 30Moovi 50

Table des Matières