The predefined parameter is shown between square brackets [ 0 ].
The writing appearing on the display is indicated between round brackets.
Refer to Figures A and B for the control unit configuration procedure.
15.1) Parameter Menu (PARAM)
1 - Automatic Closing Time (TCA) [ 10s ]
Set the numerical value of the automatic closing time from 1 to 180
seconds. Automatic closing can be deactivated by the TCA Logic,
but it is always carried out on releasing the TIMER.
2- Maximum torque (torque) [ 85% ]
Set from 60% to 99% the maximum torque that activation must be able
to provide before generating an obstacle alarm. With the maximum
value set, the control is disabled.
3- Acceleration (accel. ) [ 75% ]
Special parameter 1 on second-generation universal programmers.
Set a value from 1% to 99% for the acceleration to be applied at the
beginning of each movement.
4- Opening speed/Closing (vel. ap. ) [ 99% M60 / 50% M80 ]
Set the numerical value of the speed: 1% corresponds to the slow-down
speed, 99% to the maximum speed.
5- Braking (brake) [ 50% ]
Set from 0% to 85 % the braking to be applied during the slow-down
phase. The initial slow-down value is automatically calculated according
to this parameter and the effective movement speed.
6- Emergency braking (emer. b rake) [ 75% ]
Set a value from 75% to 99% for the braking intensity in case of revers-
ing movement or emergency braking: any values lower than those set
in the "braking" parameter will be ignored.
7- Opening value calibration (cal. ap. ) [ 082.0 ]
Special parameter 1 on second-generation universal programmers.
Set the reference value from 0,0 to 100,0 for the required opening
position (see Paragraph 17).
8- Closing value calibration (cal. ch. ) [ 021.0 ]
Special parameter 2 on second-generation universal programmers.
Set the reference value from 0,0 to 100,0 for the required closing posi-
tion (see Paragraph 17).
9- Alarm time (alarm. time) [ 30s ]
In the case of obstacle detection or photocell engagement for a period
exceeding the time set (ranging from 10 s to 20 s), the SCA contact
closes. The contact is subsequently opened by the STOP command
or by triggering of the closing limit switch. Only active when the SCA
Alarm logic is set to OFF.
If set to 0 s, the SCA contact becomes a connection to the Parky system
(see Paragraph 16).
10-Zone (zone) [ 0 ]
Set the zone number between a minimum value of 0 and a maximum
value of 127.
15.2) Logic Menu (logic. )
- TCA (tca) [ ON ]
ON: Activates automatic closing
OFF: Excludes automatic closing
Note: automatic closing on TIMER release cannot be deactivated.
- 2-step logic (2 step) [ OFF ]
ON: Enables the 2-step logic (prevails over the "3-step logic").
OFF: Disables the 2-step logic, activating the -step logic if the "3-step
logic" is OFF.
- 3-step logic (3 step) [ ON ]
ON: Enables the 3-step logic (if the "2-step logic" is OFF).
OFF: Disables the 3-step logic, activating the -step logic if the "2-step
logic" is OFF.
Response to the START impulse
Barrier
2 steps
closed
opens
on closing
open
closes
on opening
after stop
opens
- Opening Impulse lock (Ibl open) [ ON ]
ON: The Start impulse has no effect during the opening phase.
OFF: The Start impulse becomes effective during the opening phase.
- Impulse lock TCA (ibl TCA ) [ OFF ]
ON: The Start impulse has no effect during the TCA dwell period.
OFF: The Start impulse becomes effective during the TCA dwell period.
- Pre alarm (pre-alarM) [ OFF ]
ON: The blinker comes on about 3 seconds before the motor starts.
16
- MICHELANGELO
INSTALLATION MANUAL
3 steps
4 steps
opens
opens
stop
closes
closes
stop + TCA
stop + TCA
opens
opens
OFF: The blinker comes on at the same time as the motor starts.
- Hold-to-run control device (hold-to-run) [ OFF ]
ON: Hold-to-run operation: the manoeuvre continues as long as the OPEN
and CLOSE control keys are kept pressed. The radio transmitter
cannot be used.
OFF: Normal impulse operation.
- Rapid closing (fast cls ) [ OFF ]
ON: Closes barrier after photocell disengagement, before waiting for the
end of the TCA (automatic closing time) set.
OFF: Command not entered.
- Photocells on opening (photc. open) [ ON ]
ON: In case of obscuring, this excludes photocell operation on opening.
During the closing phase, it immediately reverses the motion.
OFF: In case of obscuring, the photocells are active both on opening and
on closing. When a photocell is obscured on closing, it reverses the
motion only after the photocell is disengaged.
- Photocell test (test phot) [ OFF ]
ON: Activates photocell check (see Fig. 15)
OFF: Deactivates photocell check
- Direction Reversal (Inv. dir. ) [ ON ]
ON: For right-hand fitted barrier (see Par.5.2)
OFF: For left-hand fitted barrier
- TIMER su OPEN (timer) [ OFF ]
Special dip switch 1 on second-generation universal programmers.
ON: OPEN pressed for over 3s becomes TIMER
OFF: TIMER input disabled
- SCA Alarm (alarm sca) [ ON ]
Signaling output on second-generation universal programmers.
ON: The SCA contact (terminals 21-22) behaves as follows:
with barrier open and on opening:.......contact closed (warning light on)
with barrier closed:contact open..........................(warning light off)
on closing: .........................................intermittent contact (blinking)
OFF: The SCA contact closes according to the modes set by the Alarm
Time parameter.
- Fixed code (fixed code) [ OFF ]
ON: The receiver is configured for operation in fixed-code mode.
OFF: The receiver is configured for operation in rolling-code mode.
- Radio transmitter programming (radio prog) [ ON ]
ON: This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1, T2,
T3 or T) of a transmitter already memorised in standard mode by
means of the radio menu.
2 – Within 10s press the hidden key (P1) and the normal key (T1,
T2, T3 or T) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new
transmitters can be entered before the end of this time.
This mode does not require access to the control panel.
OFF: This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate Radio
menu.
- Master/Slave (Master) [ OFF ]
ON: The control panel is set as Master in a centralised connection.
OFF: The control panel is set as Slave in a centralised connection.
15.3) Radio Menu (radio)
- Add start (add start)
Associates the required key to Start command
- Read (read)
Checks one key of a receiver; if stored it displays a message showing
the receiver number in the memory location (from 01 to 6), and the key
number (T1, T2, T3 or T).
- Eliminate list (erease 64)
WARNING! Completely removes all memorised radio control devices
from the receiver memory.
- Receiver code reading (RX code)
This displays the code entered in the receiver.
15.4) Language Menu (Language)
Allows you to set the language on the display programmer.
5 languages are available:
-
ITALIAN (TA)
-
FRENCH (FRA)
-
GERMAN (DEU)
-
ENGLISH (ENG)
-
SPANISH (ESP)
15.5) MENU DEFAULT (DEFAULT)
Restores the preset default values on the control unit.
15.6) DIAGNOSTICS AND MONITORING