Capteur 3D
13.2.13 S? Command (request current decoding statistics)
Command
Description
Type
Reply
Note
13.2.14 t Command (execute asynchronous trigger)
t
Command
Description
Executes trigger. The result data is send asynchronously
Type
Action
Reply
*
!
70
S?
Requests current decoding
statistics
Request
<number of
results><t><number of positive
decodings><t><number of false
decodings>
!
<t>
tabulator (0x09)
<number of results>
Images taken since application
start. 10 digits decimal value with
leading 0s
<number of positive decodings>
Number of decodings leading
to a positive result. 10 digits
decimal value with leading 0s
<number of false decodings>
Number of decodings leading
to a negative result. 10 digits
decimal value with leading 0s
No application active
Trigger was executed, the
device captures an image
and evaluates the result.
● Device is busy with an
evaluation
● Device is in an invalid
state for this command,
e.g. configuration mode
● Device is set to a
different trigger source
● No active application