English
10.3 HMI for electric pump
Description
1
Motor running, checked by ammeter reading
2
Electric pump running detected by Ampere of the motor
3
Start failure
4
Start-up call received from pressure switches
5
Start-up call received from float in priming tank
6
Manual start button
7
Electric pump started via button
8
Electric pump stopped via button
9
Manual stop button
10
Automatic mode switched off
11
Push to view tools
12
Pump start-up call
13
Power on
14
Cumulative alarms
15
LED Test - reset
INSTRUMENTS
Three mains voltmeter
Amperemeter
Wattmeter
Varmeter
Voltammeter
Cosphimeter
Total and partial hour meter
56
Fig. 13
Push button 11 on Fig. 13 to see the values
For three-phase voltage up to 570 V
To check Ampere on the phase of electric motor
Displays apparent power up to 750 kVA
Displays hours and minutes
WILO SE 01/2018