Données Techniques - steute ES 41 Z Instructions De Montage Et De Câblage

Masquer les pouces Voir aussi pour ES 41 Z:
Table des Matières

Publicité

ES 41 Z / EM 41 Z / ES 41 WH/90° / ES 51 Z / ES 61 Z / EM 61 Z / ES 95 Z /
//
ES 95 WH/90° / EM 95 WH/90° / ZS 70 Z / ZS 71 Z
Montage- und Anschlussanleitung / Seilzugschalter
Mounting and wiring instructions / Pull-wire switches
Instructions de montage et de câblage / Interrupteurs à commande par câble
Istruzioni di montaggio e collegamento / Interruttori a fune
Instruções de montagem e instalação / Chaves acionadas por cabo
Инструкция по монтажу и подключению / Тросовые выключатели
English
Switching elements
1 NC/1 NO or 2 NO, type Zb
Switching system
slow or snap action
Connection
screw connection terminals
Cable cross-section
max. 2.5 mm² (incl. conductor ferrules)
Cable entry
3 x M20 x 1.5
U imp
6 kV
U i
400 V
I the
10 A
Utilisation category
AC-15
I e /U e
ES 61: 16 A/400 VAC,
EM 61: 6 A/400 VAC
Max. fuse rating
ES 61: 16 A gG/gN fuse
EM 61: 6 A gG/gN fuse
Mechanical life
> 1 million operations
Indicator lamp
as option
Operation cycles
3600/h
Ambient temperature
–20 °C ... +80 °C
Actuating force
max. 50 N
Features
pull-wire function
ES 95 ...
Standards
EN 60947-5-1
Enclosure
glass-fibre reinforced, shock-proof
thermoplastic, self-extinguishing UL
94-V0
Degree of protection
IP 67 to IEC/EN 60529
Contact material
silver
Switching elements
1 NC/1 NO or 2 NO, type Zb
Switching system
slow action
Connection
screw connection terminals
Cable cross-section
max. 2.5 mm² (incl. conductor ferrules)
Cable entry
1 x M20 x 1.5
U imp
4 kV
U i
400 V
I the
6 A
Utilisation category
AC-15; DC-13
I e /U e
6 A/400 VAC; 0.25 A/230 VDC
Max. fuse rating
6 A gG/gN fuse
Mechanical life
> 1 million operations
Operation cycles
1800/h
Ambient temperature
–20 °C ... +80 °C
Contact opening
2 x 3.5 mm
Actuating force
20 N
Features
pull-wire function
ZS 70 ...
Standards
EN 60947-5-1
Design
mounting details to EN 50041
Enclosure
glass-fibre reinforced, shock-proof
thermoplastic, ultramid
Cover
glass-fibre reinforced, shock-proof
thermoplastic, ultramid
Degree of protection
IP 67 to IEC/EN 60529
Contact material
silver
Switching elements
1 NC/1 NO, type Zb
Switching system
snap action, positive break NC contacts
Connection
screw connection terminals
Cable cross-section
Cable entry
U imp
U i
I the
Utilisation category
I e /U e
Max. fuse rating
Mechanical life
Operation cycles
Ambient temperature
Actuating force
Features
ZS 71 ...
Standards
Enclosure
Cover
Degree of protection
Contact material
Switching elements
Switching system
Connection
Cable cross-section
Cable entry
U imp
U i
I the
Utilisation category
I e /U e
Max. fuse rating
Mechanical life
Indicator lamp
Operation cycles
Ambient temperature
Actuating force
Features
Français
Données techniques
ES 41 ... / EM 41 ...
Normes de référence
Boîtier
Couvercle
Etanchéité
Matière des contacts
Eléments de commutation 1 NC/1 NO or 2 NO
Système de commutation
Raccordement
8 / 16
max. 2.5 mm² (incl. conductor ferrules)
1 x M20 x 1.5
6 kV
400 V
6 A
AC-15
6 A/400 VAC
6 A gG/gN fuse
> 1 million operations
1800/h
–10 °C ... +70 °C
max. 85 N
pull-wire function
EN 60947-5-1
aluminium die-cast, powder-coated
thermoplastic, ultramid
IP 65 to IEC/EN 60529
silver
1 NC/1 NO, type Zb
slow or snap action, positive break
NC contacts
screw connection terminals
max. 2.5 mm² (incl. conductor ferrules)
2 x M20 x 1.5
ZS 71 Z: 6 kV,
ZS 71 Z RE: 4 kV
400 V
ZS 71 Z: 6 A
ZS 71 Z RE: 4 A
AC-15
ZS 71 Z: 6 A/400 VAC,
ZS 71 Z RE: 4 A/400 VAC
ZS 71 Z: 6 A gG/gN fuse
ZS 71 Z RE: 4 A gG/gN fuse
> 1 million operations
as option
1800/h
–25 °C ... +70 °C
ZS 71 Z: max. 80 N,
ZS 71 Z RE: max. 80 N
pull-wire function
EN 60947-5-1
fonte d'aluminium, revêtu par poudre
acier, revêtu par poudre
IP 65 selon IEC/EN 60529
argent
action dépendante ou rupture brusque
bornes à vis

Publicité

Table des Matières
loading

Table des Matières