INITIAL OPERATING
Mains connection
It is important to ensure that the mains supply voltage
is in accordance with the voltage to which the machine
is built. If the machine can be adjusted for use on
several different voltages then the machine must be
checked to confirm that it has been set to the correct
voltage.
Dispose of the product according to local
standards and regulations.
www.migatronic.com/goto/weee.
Connection of gas bottle
Use only gas bottles with a max. height of 100 cm. If
larger bottles are used the machine may tip over.
Configuration
MIGATRONIC
disclaims
damaged cables and other damages related to
welding with under sized welding torch and welding
cables measured by welding specifications e.g. in
relation to permissible load.
Important!
In order to avoid destruction of plugs
and cables, good electric contact is
required
when
connecting
cable and welding torch to the
machine.
Warning
Connection to generators can damage the welding
machine.
When connected to a welding machine, generators can
produce large voltage pulses, which can damage the
welding machine. Use only frequency and voltage
stable generators of the asynchronous type.
Defects on the welding machine arisen due to
connection of a generator are not included in the
guarantee.
Adjustment of wire brake
The wire brake must ensure that the wire reel brakes
sufficiently quickly when welding stops. The required
brake force is depending on the weight of the wire reel
and the maximum wire feed speed. A brake torque of
1.5-2.0 Nm will be satisfactory for most applications.
Adjustment:
- Dismount the control knob by
placing a thin screw driver
behind the knob and
thereafter pull it out
- Adjust the wire brake by
fastening or loosening the
self-locking nut on the axle of
the wire hub
- Remount the knob by
pressing it back into the groove
all
responsibility
for
earth
TECHNICAL DATA
Multimotive Duo
Current range
Voltage adjustment
Duty cycle, 100%
Duty cycle, 60%
Duty cycle, 35%
Duty cycle, 30%
Duty cycle, 15%
Open circuit voltage
1
Mains voltage
Fuse
Mains current, effective
Mains current, max.
Consumption, 100%
Consumption, open circuit
Efficiency factor
Wire dimension
Wire reel capacity
Wire speed
2
Spot welding time
2
Stitch welding time
Burn-back
3
Application class
4
Protection class
Standards
Dimensions, lxwxh
Weight
1
Delivery for other mains voltages is possible
2
The functions 4-times, spot and stitch welding can only be found
on some machine versions
3
Meets the demands made for machines which are to operate
under special working conditions
4
This machine is designed for indoor operation and meets the
requirements of protection class IP21.
10
We reserve the right to changes
220
221
20-200
20-200
11
20
105
85
125
105
135
150
155
-
200
17.2–46.8
14-30
1x230
3x400
10
16
4.0
14.7
7.3
38.0
2.8
3.4
<10
<10
0.85
0.85
0.6-1.2
0.6-1.2
5-15
5-15
2-14
2-14
0.15-2.5
0.15-2.5
0.15-2.5
0.15-2.5
0.05-0.5
0.05-0.5
S
S
IP21
IP21
EN/IEC60974-1
EN/IEC60974-5
EN/IEC60974-10 (Class A)
72x38x90
72x38x90
82
72
Units
A
A
A
A
A
A
V
V
A
A
A
kVA
W
mm
kg
m/min
sec.
sec.
sec.
cm
kg