INITIAL OPERATING
Mains connection
It is important to ensure that the mains supply
voltage is in accordance with the voltage to which the
machine is built.
Connection of gas bottle
Use only gas bottles with a max. height of 100 cm. If
larger bottles are used the machine may tip over.
Configuration
MIGATRONIC
disclaims
damaged cables and other damages related to
welding with undersized welding torch and welding
cables measured by welding specifications e.g. in
relation to permissible load.
TECHNICAL DATA
Mains voltage
Consumption (duty cycle 60%)
Fuse
Maximum input current
Open circuit voltage (DC)
Welding current range
Duty cycle, 20 %
Duty cycle, 60 %
Duty cycle, 100 %
Voltage adjustment
Insulation class
1
Protection class
Dimensions (WxHxL)
Weight
1
This machine is designed for indoor operation and
meets the requirements of protection class IP21.
all
responsibility
for
Rally MIG 160
230 V / 50 Hz
4.8 kVA
T 16 A
21 A
17.5 – 31.5 V
30 – 150 A
150 A
90 A
70 A
5
F
IP 21
230x550x665 mm
49 kg
BETJENINGSVEJLEDNING
3
4
1. On
Lights when the machine has been turned on.
2. Overheating
Lights if the welding process is automatically
stopped due to overheating of the transformer.
The light extinguishes when the transformer
temperature has dropped to normal, and weld-
ing can continue.
3. Wire feed speed control
Infinitely variable (1.0 - 10 m/min).
4. Main switch and switch for welding voltage
5. Connection of welding hose
6. Fuse
1 A slow.
8
5
1
2
6