Malfunctions

15.
MalfuncTiOns
malfunction
cause / remedial action
Actuator does
Pilot air port interchanged
not switch.
Check pilot air ports
Pilot pressure too low
See pressure specifications on the type label.
Medium pressure too high
See pressure specifications on the type label.
Valve is not
Medium pressure too high
sealed.
See pressure specifications on the type label.
Pilot pressure too low
See pressure specifications on the type label.
Flow rate
Diaphragm bulging
reduced.
Replace diaphragm.
Tab. 5:
Malfunctions
see "Fig. 24: Pneumatic connection; installation of a proximity
4)
switch".
16.
note!
4)
transport damage.
Inadequately protected devices may be damaged during
transportation.
▶ Protect the device against moisture and dirt in shock-resistant
▶ Prevent the temperature from exceeding or dropping below the
▶ Protect the pneumatic connections from damage by placing pro-
incorrect storage may damage the device.
▶ Store the device in a dry and dust-free location!
▶ Storage temperature 0 – +60 °C.
if the device is stored with tightened body screws, the dia-
phragm may be permanently deformed.
▶ If the device is stored for a prolonged period, slacken the body
damage to the environment caused by device components
contaminated with media.
▶ Ensure that the device and packaging are disposed of in an envi-
▶ Observe applicable disposal and environmental regulations.
TranspOrT, sTOrage,
pacKaging
packaging during transportation.
permitted storage temperature.
tective caps on them.
screws.
ronmentally sound manner.