Type 2000 INOX
Malfunctions
12. MALFUNCTIONS
Malfunction
Remedial action
Actuator does
Control pressure too low.
→
See pressure specifications on the rating plate.
not switch.
Medium pressure too high.
→
See pressure specifications on the rating plate.
Direction of flow reversed.
→
See identification on the rating plate.
Valve is not
Dirt between seal and valve seat.
→
Install dirt trap.
sealed.
Seat seal worn.
→
Install new pendulum disc.
Seat seal damaged, e.g. by foreign objects, swarf
or similar.
→
Install new pendulum disc.
Direction of flow reversed.
→
See identification on the rating plate.
Control pressure too low.
→
See pressure specifications on the rating plate.
Medium pressure too high.
→
See pressure specifications on the rating plate.
Valve is
Spindle seal worn.
→
leaking on the
Replacing actuator.
release bore.
Tab. 1:
Malfunctions
13. SPARE PARTS
CAUTION!
Risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable spare parts may cause injuries
and damage the device and the surrounding area.
• Use original accessories and original spare parts from Bürkert
only.
The valve set, order no. 220053, is available as a spare part for the
angle seat valve, Type 2000 INOX. This consists of:
• The pendulum disc:
consisting of
- Seal holder
- Seat seal
- Centering
• The graphite seal
This can also be ordered separately
english
19