Type 2730 / 2731 / 2731K
Electrical control unit
8.
elecTrical cOnTrOl uniT
The valve Type 2730 / 2731 / 2731K can be combined with fol-
lowing control units:
• Type 8630
Positioner TopControl Continuous
• Type 8635
Positioner SideControl
• Type 8692
Positioner TopControl
• Type 8694
Positioner TopControl Basic
• Type 8792
Positioner SideControl
• Type 8693
Process controller TopControl
• Type 8793
Process controller SideControl
Follow instructions for use in the Ex area!
See chapter "3.1".
The electrical connection of the control unit is described in
the respective operating instructions for the control unit.
9.
MalfuncTiOns
malfunction
cause /remedial action
Actuator does
Pilot air port interchanged
not switch.
CFA:
CFB:
Pilot pressure too low
See pressure specifications on the type label.
Medium pressure too high
See pressure specifications on the type label.
Valve is not
Medium pressure too high
sealed.
See pressure specifications on the type label.
Pilot pressure too low
See pressure specifications on the type label.
Flow rate
PTFE diaphragm bulging
→
reduced.
Replace diaphragm.
Tab. 12: Malfunctions
see "Fig. 19: Pneumatic connection"
5)
english
5)
Connecting lower pilot air port
Connecting upper pilot air port
25