Single sided model:
Characteristic
Power supply
Nominal current
Electrical insulation
Operating temperature
Mains power terminal block
Illumination power supply terminal block
CTR relay circuit
Cable entries by cable glands.
Dimensions
Double sided model:
Characteristic
Power supply
Nominal current
Electrical insulation
Operating temperature
Mains power terminal block
Illumination power supply terminal block
CTR relay circuit
2.2 Single sided (SF) clock
- Open the clock by turning the 2 bolts (3)
a quarter turn using the key (1), then pulling
the clock face assembly forward (compass opening).
The compass-opening system allows
for rapid and reliable maintenance of the
illumination without putting the front of the clock down.
- Put the clock in position and attach it with M8 screws (4), without tightening it down, after passing
the cables (between Ø7 and Ø10) through the cable glands (5).
- Make the required connections (see § Power supply,
page 7, and § Setup and initial time setting, page 7).
- Screw the clock down firmly.
- Switch on power to the clock.
- Close the clock.
100-240V +/- 10% 50/60Hz
0.3-0.2 A
Class III
-20 to +80°C
3 terminals E, N and L, 0.75² to 2.5²
2 terminals N and L, 0.75² to 2.5²
Max 3A at 30V. Min 10mA at 5V
Mains cable: CM10P-sheath Ø 5 to 10 mm
Illumination cable: CM10P-sheath Ø 5 to 10
mm
100-240V +/- 10% 50/60Hz
0.45-0.25 A
Class III
-20 to +80°C
3 terminals E, N and L, 0.75² to 2.5²
2 terminals N and L, 0.75² to 2.5²
Max 3A at 30V. Min 10mA at 5V
Values
Values
21