- Synchronisation failure: this parameter enables detection of synchronisation faults with the
- Hands position control : this parameter enables/disables detection of faults in the position of the
- Shock: this parameter enables/disables detection of shock to the clock (accelerometer measuring
clock movement, 3 levels of sensitivity).
- Open case: this parameter enables/disables detection of the clock being opened.
- Lighting failure: this parameter enables/disables detection of a fault with the clock illumination.
- Battery failure: this parameter enables/disables detection of low battery level.
- Battery maintenance : this parameter defines the life span of the battery (20 months to 50 months).
- Power failure: this parameter enables/disables detection of a power supply fault (mains power cut).
- Temperature: this parameter enables reporting of high or low temperature threshold breaches
(variable temperature range).
- Periodic Status: this parameter enables periodic sending (configurable interval) of an alarm to
Information : the errors or faults reported are minor and do not in themselves require a
Warning: the errors or faults reported are to warn the user, and require a visit by a
maintenance technician to correct the fault.
Critical: the errors or faults reported are serious and require a prompt visit by a maintenance
technician to correct the fault.
The Save button saves the configuration data entered.
The Send status trap button sends a status trap to all configured SNMP Managers in order to
confirm that monitoring has been correctly configured.
30
master clock (Sigma type) or the time server (Netsilon type):
Multicast: Alarm triggered when the multicast synchronisation is absent
for at least 1hour.
Unicast: Alarm triggered when the unicast synchronisation is absent for
3 times the duration of the poll (periodicity) and at least 1 hour
(allowing for the NTP server maintenance).
hands.
indicate to the SNMP Manager that the clock is still "alive". The alarm consists
of the clock's status.
visit by a maintenance technician to correct the fault.