4.2

Positioning the system

▶ Align the system tank horizontally on a clean layer. Alternatively, the system
tank can also be fastened with threaded rods (max. M10) fed through the
eyes in the edge of the system tank.
▶ The profile lip seal must be placed in the tank groove.
▶ Determine the height of the planned ground surface and check whether an
additional extension section will need to be installed.
The height of the upper section is adjustable. However, the minimum inser-
tion depth (47 mm) of the upper section must be taken into account. The
upper section can be shortened accordingly if necessary.
▶ Trial-fit upper section and cover plate.
L The cover plate also provides protection during the construction period.
L In order to ensure that the subsequent removal of the upper section is as
easy as possible, the profile lip sealing can be greased afterwards.
016-059
Installation and operating manual
Max.
Fig. [6]