4.4
Fit inlet and conduit pipe
Conduit pipe connection nozzle (DN50):
L The conduit pipe is to be installed with max. 45° bends.
▶ Check whether the seal is in the socket. ➊
▶ Feed the mating part for the nozzle into the drilled opening from the inside. ➋
▶ Screw the mating part on hand-tight such that it is securely sealed. ➌
▶ Slide the pipe in as far as it will go. ➍
▶ Repeat these steps again for the inlet.
Fitting the inlet pipe:
▶ Slide on sewage ground pipe with double socket (DN 100) or PE welding socket
onto pre-assembled inlet nozzle (opposite conduit pipe) and connect firmly.
▶ Check the positioning of the system tank and the tight fit of the connection on
the inlet nozzle.
016-059
Installation and operating manual
1
2
3
4
Fig. [10]
45