2
20 m to 50 m
4 mm
230 V – 240 V / 1~:
up to 20 m
2.5 mm
2
20 m to 50 m
4 mm
200 V / 3~:
up to 10 m
3.5 mm
10 m to 30 m
5.5 mm
Connection to the power supply socket
Before connection to the power supply,
check that the machine is switched off –
see "Switching off the machine"
1
2
Remove the power plug from the
N
upper holder (1)
Swivel the lower holder (2) upward
N
and remove the power cord
Plug the power cord or extension
N
cord into a properly installed outlet
RE 232, RE 272 PLUS, RE 282 PLUS

Switching On

2
Turn on water supply
N
NOTICE
2
The machine may only be switched on
2
when the water intake hose is connected
and the water supply has been turned
on. Otherwise the machine may be
damaged due to lack of water.
Completely unroll the high-pressure
N
hose
Turn the master switch to I – now
N
the machine is in standby mode
Point the spray gun at the object to
N
be cleaned – never at persons!
When the machine is switched on,
voltage fluctuations that occur under
unfavorable mains conditions (high
power line impedance) may negatively
affect other connected electrical
appliances.
Trouble is not anticipated at power line
impedances less than 0.15 ohms.
Machine with hose reel
NOTICE
Always completely unroll the high-
pressure hose from the hose reel. The
high water pressure causes the high-
pressure hose to expand. This can also
damage the hose reel or high-pressure
hose.
1
Pull out hose reel stop (1)
N
Completely unroll the high-pressure
N
hose
English