Connecting To Power Supply; Switching On - Stihl RE 108 PLUS Notice D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 55

Connecting to Power Supply

The voltage and frequency of the
machine (see rating plate) must match
the voltage and frequency of the power
connection.
The minimum fuse protection of the
power connection must comply with the
specifications – see "Specifications".
The machine must be connected to the
power supply via an earth-leakage
circuit breaker to disconnect the power
supply if the differential current to earth
exceeds 30 mA for 30 ms.
The power connection must correspond
to IEC 60364-1 and relevant national
regulations.
When the machine is switched on,
voltage fluctuations that occur under
unfavorable mains conditions (high
power line impedance) may negatively
affect other connected electrical
appliances. Trouble is not anticipated at
power line impedances less than
0.15 Ω.
Depending on the supply voltage and
cord length, the minimum conductor
cross section of the extension cord must
be as follows:
Cord length
Minimum cross
section
220 V – 240 V:
up to 20 m
1.5 mm
20 m to 50 m
2.5 mm
100 V – 127 V:
up to 10 m
AWG 14 / 2.0 mm
10 m to 30 m
AWG 12 / 3.5 mm
RE 108, RE 118, RE 128 PLUS
Connection to the power supply socket
Before connection to the power supply,
check that the machine is switched off –
see "Switching off the machine"
Swivel the lower holder upward and
N
remove the power cord
Plug the power cord or extension
N
cord into a properly installed outlet
2
2
2
2

Switching On

Turn on water supply
N
NOTICE
The machine may only be switched on
when the water intake hose is connected
and the water supply has been turned
on. Otherwise the machine may be
damaged due to lack of water.
Completely unroll the high-pressure
N
hose
Turn the master switch to I – now
N
the machine is in standby mode
English
37

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Re 118 plusRe 128 plus

Table des Matières