CONNECTION/WIRING DIAGRAM
TAB
Model
Amperage
Amps
Sense Combi-U 7
26
Sense Combi-U 8
30
Note: Heating elments do not change for voltage changes. The heater output will changed based on the voltage applied to heater.
16
15
14
10
3 x 14 AWG
RJ10 4P4C
RJ10 4P4C
max 75 feet - Combi Elite
*
max 300 feet - Combi Pure
**
Figure 19: Wiring diagram
1. NTC Sensor - Combi Pure.
2. Ext switch (External switch Optional)
3. N/A
4. N/A
5. N/A
6. Sensor (humidity- and temperature) - Combi Elite.
7. N/A
8. N/A
9. Controls panels (Pure or Elite).
1:A
2:B
Pin
1
3:12V
4:GND
Fig 20a: Connecting the humidity- and temperature sensor -
Combi Elite
1.
Modular plug (RJ10, see Fig 19)
2.
Humidity- and temperature sensor
208 V 1 Phase
Output
Wire Size
Amperage
kW
AWG
5,3
10
6,3
8
1 2
3 4
5
6
7
8
13
12
* **
RJ10 4P4C
RJ10 4P4C
A
2
B
11
12
240 V 1 Phase
Output
Wire Size
Amps
kW
AWG
30
7,0
8
35
8,3
8
9
11
5,3-8,3 kW
208/240 V~
10. Heater
11. Terminal for connection of electrical cable
12. Control panel (connect to positions 6-9)
13. Sensor - Combi Pure (connect to NTC position 1)
13. Humidity- and temperature sensor - Combi Elite
(connect to positions 6-9)
14. Light/terminal for connection of light
15. Door contact (option)
16. External switch (option)
Fig 20b: Connecting the humidity- and temperature sensor -
Combi Elite
R=Red, G=Green, W=White, B=Black
G
1 2 3 4
R
A
G
B
11
W
12
B
9
14