INSTALLATION GUIDE
BEFORE INSTALLATION
Parts
Check that the following parts are included in the packaging:
2
3
4
1
6
5
7
9
10
8
Figure 1: Sauna heater/control panel parts
1.
Sauna heater
2.
Herb bowl/air humidifi er
3.
Herb bowl
4.
Brackets
5.
Warning and Caution plates for the room in multiple languages
6.
Screws B 4 x 6.5 x 6 for Warning and Caution plates
7.
Connectors x 3
8.
Spacers x 4
9.
Screws x 4
10. Bracket screws x 2
11. NTC-sensor (Combi Pure)
12. Screw B4x6,5 (x 1 Combi Pure) (x 2 Combi Elite)
13. Sensor cover (Combi Pure)
14. Clips TC (3-5) x 10 pieces
15. Plastic plugs 25x5 x 2 pcs
16. Screws B6x25 x 2 pcs
17. Humidity- and temperature sensor with cover (Combi Elite)
18. Cable between heater and humidity- and temperature sensor,
RJ10 4P4C, cable length 4 m x 1 pce (Combi Elite)
19. Control panel (Elite Wifi or Pure)
20. Cable between heater and control panel, RJ10 4P4C, cable
length 5 m x 1 pce
21. Cable tie
22. Clips C 3x5 x 10 pieces
23. Modular plug 4, 4/4RJ10 x 2
24. Plastic plugs 25x5 x 3 pcs
25. Screws B6x25 x 3 pcs
26. Rock guard
27. Protection hose Ø14x150 mm x 3 pcs, for RJ10 cables (sen-
sor, control panel, door switch)
12
11
14 15 16
13
17
18
19
20
Pure
Elite
WiFi
21
25
22
24
23
26
27
Contact your dealer if anything is missing.
Control panel Pure is supplied with Sense Combi Pure.
Control panel Elite WiFi is supplied with Sense Combi Elite.
See separate guides.
Installation requirements
To ensure safe use of the heater, check that the following criteria
are met:
•
Electrical wiring should be installed in accordance with NEC
and all state and local codes.
•
Fuse size (A) and power cable size (AWG) must be suitable
for the heater (see The section called Connection/wiring
diagram, Page 9.
•
The sauna ventilation must comply with the instructions in
this manual (see The section called Positioning the inlet vent,
Page 5, The section called Positioning the outlet vent, Page
5).
•
The position of the sauna heater, control panel, and sensors
must comply with the instructions in this manual.
•
The heater output (kW) must be suitable for the sauna
volume (cu.ft.) (See Table 1, Page 3). The minimum and
maximum volumes must not be exceeded.
•
NOTE: A GFCI device is not required by ETL. A GFCI may
be installed if required by local codes. However, GFCI devic-
es will tend to nuisance trip during use of the product.
Table 1: Voltage and sauna volume
Model
Voltage
Sense Combi-U 7
208 V
SCU7
240 V
Sense Combi-U 8
208 V
SCU8
240 V
Installation tools
The following tools and materials are needed for installation and
connection:
•
level
•
tape measure
•
electric drill
•
screw drivers
Installation planning
Before starting to install your sauna heater:
•
Plan the sauna heater positioning (see the Heater positioning
- normal installation section, page 4).
•
Plan the control panel positioning (see the attached instruc-
tions for the control panel for allowable positioning).
•
Plan the sensor positioning (see Figure 3, page 4).
•
Position the air intake vent (see the Air intake vent positioning
section, page 5).
•
Position the air exhaust vent (see the Air exhaust vent posi-
tioning section, page 5).
•
Plan the electrical installation (see the Connection/wiring
diagram section, page 9).
Sauna volume
Sauna volume
min. cu.ft.
max. cu.ft.
175
265
175
320
250
360
250
440
3