CONNECTION/WIRING DIAGRAM

400-415 V 2N~
Output kW
Amperage
2,2
-
4,5
10
1
Figure 15: Wiring diagram
1. Heater
2. Terminal for connection of electrical cable

SELF-INSPECTION OF THE INSTALLATION

To inspect the installation:
1.
Switch on the mains supply to the heater from the distribution
board.
2.
Start the heater (see User Guide).
3.
Check that the two tubular elements start heating up (go red).
Unusual voltages/numbers of phases
Contact TylöHelo Customer Service before connecting to voltages
or numbers of phases that are not listed in the wiring diagram
(see Figure 14).
Please keep these instructions.
In the event of problems, please contact the retailer where you purchased
the equipment.
© This publication may not be reproduced, in part or in whole, without the
written permission of TylöHelo. TylöHelo reserves the right to make chang-
es to materials, construction and design.
(A)
Wiring area mm²
-
1,5
1
2
A 4 x 1,5 mm²
B 3 x 4 mm²
C 3 x 1.5 mm²
200-240 V 1N~/2~
(B)(C)
Amperage
Wiring area mm²
10
1,5
20
4
4,5 kW
400 V 2N~
2,2 kW
200 - 240 V 1N~/2~
L1/N
L2
4,5 kW
200 - 240 V 1N~/2~
L1/N
L2