Connection/Wiring Diagram; Checking Installation - Tylo CURVE Notice D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
8
Unusual voltages/numbers of phases
Before connecting to voltages or numbers of phases not listed in
the wiring diagram Figure 11, Page 8, contact Tylö Customer
Service.

CONNECTION/WIRING DIAGRAM

400-415 V 3N~/3~
Output kW
Amperage
6,6
10
8
12
Alt. 1
Alt. 2
1
Figure 11: Wiring diagram
1. Heater
2. Terminal for connection of electrical cable

CHECKING INSTALLATION

To check the installation:
1.
Switch on the mains supply to the heater from the distribution
board.
2.
Start the heater (see User Guide).
3.
Check that all three tubular elements start to heat up (go
red).
(C, D, E)
Wiring area
mm²
1,5
2,5
1
2
A 3 x TAB
B 4 x TAB
C 5 x TAB
D 4 x TAB
E
4 x TAB
230-240 V 3~
(B)
Amperage
Wiring area
mm²
17
4
20
4
E
Keep this user guide!
In the event of any problems, please contact the retailer where you pur-
chased the equipment.
© This publication may not be reproduced, in part or in whole, without
the written permission of Tylö. Tylö reserves the right to make changes in
materials, construction and design.
230-240 V~
(A)
Amperage
Wiring area
mm²
29
10
35
10

Publicité

Table des Matières
loading