SENSE PLUS PURE 2.0 Quick-Start Tip Sheet 2900 5282 This page to be used in conjuction with Tylo Full Manual included 2018-09-12 CONNECTION/WIRING DIAGRAM 208 V 1 Phase 240 V 1 Phase Model Amperage Output Wire Size Amperage Output Wire Size...
Page 2
or any other heater components. Extra care should be taken when closing junction box cover to ensure wires are not being pushed out of position. Some prefer or are required to make a weather-proof connection. If so, you may use Liquid tight conduit for the wire exposed wire to connect to heater Sensor Sensor Location:...
Page 3
SENSE PURE/ELITE USA 2016-10-18 ENGLISH INSTALLATION / USER GUIDE FRANÇAIS NOTICE D’INSTALLATION ET D’UTIL- ISATION 2900 5280...
Page 4
USER GUIDE............... 11 INSTALLATION GUIDE..........3 GENERAL INFORMATION ..........11 BEFORE INSTALLATION ............ 3 Parts ............... 3 PRIOR TO USE ..............11 The fi rst time you use the heater ......11 Installation requirements ........3 Prior to each use ............ 11 Installation tools ............
Page 5
INSTALLATION GUIDE Installation requirements BEFORE INSTALLATION To ensure safe use of the heater, check that the following criteria are met: Parts • Electrical wiring should be installed in accordance with NEC Check that the following parts are included in the packaging: and all state and local codes.
Page 6
Positioning the control panel The control panel can be installed inside or outside of the sauna room. The control panel must be correctly positioned with regard to safety distances below when installed inside the sauna room Figure 2: Schematic diagram of installation Sauna heater Control panel Sensor...
Page 7
Sauna room ventilation Removing the Rock Guard In a sauna, the air should be changed about 6 times an hour. See Unscrew the two screws on the side of the heater and lift the Figure 6. rock guard upwards, see Figure 7. (This is necessary when fi lling the stone compartment or cleaning the fragrance holder and air It is recommended that ventilation openings meet the require- humidifi...
Page 8
Typical wall construction Figure 8: Typical wall construction INSTALLATION Light cable (if connected) Figure 10: Circuit board Terminal for connection of Electrical cable light (if connected) Sauna heater installation Terminal for connection of elec- Strain relief connector for It is easiest to prepare for installation with the heater lying down. trical cable cables to modular contacts Cable grommet (x6)
Page 9
Figure 12: Dimensioning 1. 10.31 in 2. 6 in 3. 16.3 in 4. 8.11 in Figure 16: Installing the sensor 10. Fit herb bowl/air humidifi er (see Fig. 13). Figure 13: Fitting the fragrance holder/air humidifi er Hang the heater on the screws see Fig. 14. Figure 17: Seal any holes Unusual voltages/numbers of phases Contact Tylö...
Page 10
CONNECTION/WIRING DIAGRAM 208 V 1 Phase 240 V 1 Phase Model Amperage Output Wire Size Amperage Output Wire Size Amps Amps Sense U 7 Pure/Elite Sense U 8 Pure/Elite Note: Heating elments do not change for voltage changes. The heater output will changed based on the voltage applied to heater. ELITE PURE 5,3-8,3 kW...
Page 13
USER GUIDE Default settings Using the control panel for the fi rst time: See instructions supplied with the control panel. GENERAL INFORMATION Prior to each use Congratulations on your new sauna heater! Follow this user guide Check the following to get the most from your purchase. Check that: Wet and dry saunas are forms of bathing which originate way •...
Page 14
Tylö Sauna Fragrance comes in diff erent variants and fragrances. Check the stone compartment Go to www.tylo.com to see the full range. Check the stone compartment at least once annually or as many times per year as the heater is used per week.
Page 15
TROUBLESHOOTING Temperature Safety Switches The heater's temperature protection devices: • PCA - The temperature safety on the PCA in the heater is de- signed to prevent components being damaged by overheating. If the safety switch is triggered, an error code shows on the control panel display.
Page 16
Troubleshooting the sauna heater Information! Contact the dealer during the guarantee period in the event of faults. See the instructions for the control panel for details of faults not covered in this user guide. Table 1: Troubleshooting the sauna heater Symptom Possible cause Remedy...
Page 17
SPARE PARTS LIST Figure 7: Spare parts 1 U8 Pure/Elite Tubular Elements 3001-924 U7 Pure/Elite Tubular element 3001-920 Stone compartment Circuit board Elite 9600 0068 Circuit board Pure 9600 0067 Terminal block 9600 0723 Sauna heater temperature safety switch 3119-607 Strain relief connector 9600 0554 ROHS (RESTRICTION OF HAZARDOUS SUBSTANCES)
Page 18
HEATER WIRING DIAGRAM BACK MIDDLE FRONT High Limit Control Heater Circuit board GND M X17 X18 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 X13 X14 X15 X16 GND GND 208 V~ 240 V~ Type Sense L2 GND Plus-U 7 120 V~ N 208-240V, 1-ph...
Page 19
NOTICE D'UTILISATION............26 NOTICE D'INSTALLATION............18 INFORMATIONS GÉNÉRALES ............26 AVANT L'INSTALLATION ..............18 Pièces ..................18 AVANT L'UTILISATION ............... 26 Avant la première utilisation du poêle ........26 Exigences relatives à l'installation .......... 18 Avant chaque utilisation ............26 Outils d'installation ..............
Page 20
NOTICE D'INSTALLATION Exigences relatives à l'installation Pour garantir une utilisation sûre du poêle, vérifi ez que les critères suivants sont respectés : AVANT L'INSTALLATION • Le câblage électrique doit être installé conformément au code national d'électricité américain (NEC) et à tous les co- Pièces des nationaux et locaux du pays où...
Page 21
Emplacement du panneau de commande Le panneau de commande peut être monté à l'intérieur ou à l'ex- térieur de la cabine de sauna. Le panneau de commande doit être correctement positionné en ce qui concerne les distances de sécurité ci-dessous, lorsqu'il est installé...
Page 22
Ventilation de la cabine du sauna Retrait du protège-pierres Dans un sauna, l'air doit être renouvelé environ 6 fois par heure. Desserrer les deux vis sur le côté du poêle et soulever le Voir la Fig. 6. protège-pierres vers le haut, voir Fig. 7. (Ceci est nécessaire lors du remplissage du compartiment de pierres ou du nettoyage du Il est recommandé...
Page 23
Construction murale typique CONSTRUCTION MURALE PRÉDÉCOUPÉE TYPIQUE 1/2" 2x4" panneau mural cadre isolation en fi bre de verre barrière vapeur en fi lm d'aluminium bois tendre à languette et rainure 1/2" panneau mural Fig. 8 : Construction murale typique Câble d’éclairage (le cas Fig.
Page 24
Fig. 12 : Cotes 1. 262 mm (10.31 po) 2. 270 mm (6 po) 3. 532 mm (16.3 po) 4. 206 mm (8.11 po) Fig. 16 : Montage du capteur 10. Coupelle à herbes/humidifi cateur (voir la fi gure 13). Fig.
Page 25
SCHÉMA DE RACCORDEMENT/BRANCHEMENT 208 V monophasé 240 V monophasé Modèle Intensité A Puissance Section du con- Intensité A Puissance Section du con- ducteur AWG ducteur AWG Sense U 7 Pure/Elite Sense U 8 Pure/Elite ELITE PURE 5,3-8,3 kW 208/240 V~ RJ10 4P4C 3 x 14 AWG RJ10 4P4C...
Page 28
Faire fonctionner le poêle pour chasser l'odeur d'appareil neuf. NOTICE D'UTILISATION Pour chasser « l'odeur d'appareil neuf » dégagée par le poêle : Faire chauff er le sauna pendant environ une heure. Le réservoir INFORMATIONS GÉNÉRALES d'eau n'a pas besoin de fonctionner. Il peut se produire un léger dégagement de fumée.
Page 29
Fig. 5 : Nettoyage du récipient à parfum et de l'humidifi cateur Le parfum de sauna Tylö existe en diff érentes variantes et odeurs : Vous trouverez la gamme sur www.tylo.com. Contrôler le réservoir à pierres Contrôler le réservoir à pierres au moins une fois par an ou autant de fois par an que le poêle est utilisé...
Page 30
DÉPANNAGE Protections thermiques Les dispositifs de protection thermique du poêle : • PCA - La protection thermique sur le PCA qui équipe le poêle vise à protéger de la surchauff e les éléments électroniques. Si la protection thermique est déclenchée, un code d'erreur s'affi che sur le panneau de commande.
Page 31
Dépannage du poêle de sauna Remarque ! Contacter le revendeur pendant la période de garantie en cas de défauts. Consulter les instructions pour le panneau de commande pour les détails ou défauts non couverts dans cette notice d'utilisation. Tableau 1 : Dépannage du poêle de sauna Symptôme Cause probable Mesure à...
Page 32
LISTE DES PIÈCES DE RECHANGE Fig. 7 : Pièces de rechange 1 U8 Pure/Elite Résistances tubulaires 3001-924 U7 Pure/Elite Résistance tubulaire 3001-920 Réservoir à pierres Carte électronique Elite 9600 0068 Carte électronique Pure 9600 0067 Bornier 9600 0723 Protection thermique du poêle de sauna 3119-607 Connecteur anti-arrachement 9600 0554 ROHS (RESTRICTION OF HAZARDOUS SUBSTANCES)
Page 33
SCHÉMA DE CÂBLAGE DU POÊLE ARRIÈRE BACK MÉDIAN MIDDLE AVANT FRONT Protection thermi- High Limit Control que Poêle Heater Circuit imprimé Circuit board GND M X17 X18 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 X13 X14 X15 X16 GND GND 208 V~ 240 V~...