DESCRIPTION OF THE PRODUCT
1
ELEMENTS OF THE COMPLETE INSTALLATION
1
Operator 1 (VULCAN)
2
Operator 2 (VULCAN)
3
Flashing light with antenna
4
Leaf 1
5
Leaf 2
6
Exterior photocells
7
Key switch (key device)
8
Wall button (key device)
9
Control board
10 Connections box
11 Underground electrical installation
12 Interior photocells
13 Electrolock
14 External closing stopper
15 Opening stopper
16 Traffic light
ELECTRICAL WIRING:
Element
A: Main power supply
B/F: Flashing light / antenna
C: Photocell (Tx / Rx)
D: Pushbutton or key switch
E: Operator (motor / encoder)
Fig. 1
Elements of the complete installation
The safe and correct operation of the
installation is the responsibility of the installer.
The closing (14) and opening (15) limit switches are
essential .
The photocells (6) and (12) provide additional safety
to that already provided by the control board. For
greater safety, Erreka recommends installing the
photocells (6) and (12).
Nº wires x section
2
3x1.5mm
2
2x0.5mm
/ coaxial cable 50
2
2
2x0.5mm
/ 4x0.5mm
2
2x0.5mm
2
2
4x0.75mm
/ 3x0.5mm
The installation starts up using the push button (8)
or key switch (7), or using the radio transmitter.
Maximum length
30 m
k
(RG-58/U)
10 m
30 m
25 m
20 m
Control board VIVO-M203(M)
English
E239B
63