STARTING UP AND PROGRAMMING
Main Functions Programming (D1= "F")
D1 D2
Parameter
F
1
Key devices (key command
using pushbuttons ST1 and
ST2).
With F101 the gate (total or
pedestrian) can be kept
open by keeping ST1 or ST2
pressed down respectively.
T h i s a l l o w s t h e t i m e
scheduler to be used in
combination with F2 and/or
F4 K 00.
2
Step-by-step or automatic
a
operation mode and stand-
b y t i m e ( in s e c o n d s ) in
automatic mode
3
Pedestrian opening (%)
4
Pedestrian closing mode
a.
For further details, see "Key commands and operating modes" on page 65
1 Press ENTER to access the programming menus. The
display lights up and D1 flashes.
2 Press the buttons ^ and
F flashing. Press ENTER to confirm. D2 flashes.
3 Press the buttons ^ and
parameter appears. Press ENTER to confirm. D3 and
D4 flash.
84
Installation Guide
D3
D4
0
0...4
0..5.
0...9
0...9
0...9
0...5
0...9
until D1 shows the letter
V
until the required D2
V
Default
Options or values
option
01
00: ST1 and ST2 without effect, key
commands are made by radio
(channel 1: total opening-closing,
c h a n n e l 2 : p e d e st r i a n o p e n i n g -
closing)
01: ST1 total opening-closing,
ST2 pedestrian opening-closing
02: ST1 total opening, ST2 total closing
03: dead-man mode (the display shows
HP.)
04: dead-man mode in closing
00
00: step-by-step mode;
01: automatic mode and stand-by time 1
second
...
59: automatic mode and stand-by time 59
sec.;
1.0:1 min. 0 sec.,
etc, maximum 4 minutes
40
00: pedestrian opening is not carried out,
10: 10% of total opening, etc
00
00: step-by-step mode
01: automatic mode and stand-by time 1
second;
...
59: automatic mode and stand-by time 59
sec.;
1.0: 1 min. 0 sec.;
...; maximum 4 minutes
.
4 Press the buttons ^ and
D4 value appears (see chart). Press ENTER to
confirm.
5 Press ESC to return to the previous display.
Operating mode, programmed using F1, can be
modified using A9 (see "Advanced Functions
Programming (D1= "A")" on page 85).
until the required D3 and
V