Erreka VIVO-M203 Manuel De L'installateur page 76

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
INSTALLATION
Peripheral connections (valid for any type of operator and type of door or gate)
R.E.
Plug-in receiver
ANT
Antenna connection
Traffic light card (with parameter Ab00) or
EPS1
brake card (with parameter Ab01, see
connection diagram on page 71
AUX
Output 24Vdc (cable connectors + and
AUX)
FT
Output 24Vdc for photocells with testing
(cable connectors -FT and +)
A.T. - ST1
Key device (configurable by F1XX)
S.CIE - FT1 Safety device in closing* (photocell,
parameter C5)
Key device (configurable by F1XX)
A.P. - ST2
S.APE - FT2 Safety device in opening * (photocell,
parameter C4)
* : in swing gates, , S.APE (C4) refers to the interior photocell and S.CIE (C5) to the
exterior photocell (instead of opening and closing, respectively).
We recommend checking the accessory instructions to carry out the connections
with the control board.
72
Installation Guide
STOP Emergency stop pushbutton (normally closed)
SCA SCA light (24Vdc)
EC
Electrolock (17Vdc)
LG
Garage light (voltage free output)
VIVO-M203: 230V, max 2,300W resistive
VIVO-M203M: 125V, max 1,250W resistive
DEST Flashing light; 60W max
VIVO-M203: 230Vac, VIVO-M203M: 125Vac
LB/LR Mechanical strip / resistive strip
F1
Peripheral fuse (24V, 315mA)
F2
Fuse (230V-500mA)
F3
Fuse MOT1
VIVO-M203: 2.5A; VIVO-M203M: 6.3A
F4
Fuse MOT2
VIVO-M203: 2.5A; VIVO-M203M: 6.3A