DESCRIPTION OF THE PRODUCT
ST1 total opening, ST2 total closing (F102)
Dead man mode (F103)
Dead man mode in closing (F104)
Step-by-step mode (F200)
Opening (with alternative stop): is started by
operating the key device (magnetic key, key switch,
transmitter etc, in accordance with the configuration
F100, F101, F102, F103, F104).
• Collective opening (A901): during opening, the
control board does not obey key commands (the
gate cannot be stopped using key devices).
• Opening with alternative stop (A902): if a key
command is sent during opening, the gate comes to
a stop. A key command must be sent to close it.
If F200 is selected, A903 becomes A902.
66
Installation Guide
With F102 selected, pushbutton ST1 carries out total
opening and pushbutton ST2 carries out total closing.
Opening: this is done by continuously operating the
ST1 key device (magnetic key, key switch, pushbutton,
etc). The radio transmitter cannot be used in this case.
Standby: the gate remains open indefinitely until the
key device is operated.
Closing: this is done by continuously operating the ST2
key device (magnetic key, key switch, pushbutton, etc).
The radio transmitter cannot be used in this case.
Opening: starts by briefly operating key device ST1
(magnetic key, key switch, pushbutton, etc).
Standby: the gate remains open indefinitely until the
key device is operated.
Closing: this is done by continuously operating the ST2
key device (magnetic key, key switch, pushbutton, etc).
The radio transmitter cannot be used in this case.
M239A
Standby: the gate remains open indefinitely until the
key device is operated.
Closing: the closing operation is started by operating
the key device, in accordance with the configuration
F100, F101, F102, F103, F104.
If the key device is operated during closing, the gate
stops, reverses operation direction and then opens
completely.