MAGIC
Quick installation and programming guide
This quick guide is a summary of the complete installation manual. The manual contains safety warnings and
other explanations which must be taken into account. The installation manual can be downloaded by going
WARNING
to the "Downloads" section of Erreka website:
http://www.erreka.com/Automatismos/descargaDocumentos.aspx
*
2
4 x 1mm
(max. 20m)
2
Rx: 4 x 0,5mm
/
2
Tx: 2 x 0,5mm
(max. 30m)
TA
VERY IMPORTANT:
The TC closing limit switch and the TA
opening limit switches must be installed
in all cases.
Electrical wiring
A: Main power supply
B: LUMI flashing light
C: Photocells (Rx/Tx)
D: Pushbutton/key switch
E: Operator *:
2
motor: 4x1mm
2
brake: 2x1mm
encoder: shielded cable 2x0.5mm
F: LUMI built-in antenna
G: Electrolock
Elements of the complete installation
G
2 x 0,75mm
2
(max. 20m)
2
In dual leaf facilities without brake or encoder,
the following should be taken into account when
programming the operations: when programming
the closing of leaf 2 and the leaf reaches the closing
limit switch, wait for a time equal to the lapse
between leaves before pressing ST1 to end
programming. This ensures that, during the closing
operation, leaf 2 remains at the closing limit switch
during lapse until leaf 1 closes completely.
TC
TA
The electrolock is obligatory for operators without lock
(MA210 and MA250). For operators with lock, the
electrolock must be used for gate leaf lengths of over
1.8m.
*NOTE: the electrical installation of the operator can be
done correctly and straightforwardly using the cable with
AYCY8 code, which ERREKA can supply by metre. This cable
has the characteristics 4x1mm
and was developed specifically for this use.
English
2 x 0,5mm
2
(max. 20m)
RG-58/U
2 x 0,5mm
2
(max. 20m)
2
3 x 1,5mm
(max. 30m)
E248A
2
2
2
+2x1mm
+ ((2x0.5mm
))
5