Starting Up And Programming; Connection To The Mains; Display And Leds - Erreka VIVO-M203 Manuel De L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35

STARTING UP AND PROGRAMMING

1

CONNECTION TO THE MAINS

1 Connect the control board to the electricity supply:
the display should show CL.
Reset (rS): after connecting the electrical power
and activating any of the command devices, the
gate opens to the limit switch; in the following
operation, it closes until it finds the limit switch,
assigning the position "gate closed" to it.
2

DISPLAY AND LEDS

Display indications during operation
EDGE
P24 P25
P13 P14 P15 P16
P17 P18 P19 P20
P21 P22 P23
-FT
AUX
(Test)
24 Vdc
ENCODER1
ENCODER2
P1 P2 P3
P4 P5 P6
P7 P8
P9 P10
P11 P12
D1:
Display Menus
D2:
Display Parameters
D3 - D4: Parameter value display
After 15 minutes without pressing any key,
the display shows a horizontal segment in D4.
It is reactivated when pressing the key ENTER,
ESC, UP or DOWN.
CN13
G7 G8
G9 G10
G4
G5
G6
G1
G2
G3
N
L
POWER - 230V
MOTOR2
MOTOR1
M239C
CHECKING
AND
DIRECTION: after installing the operators, it is
necessary to check turning direction using the
parameters C1 or C2 (see "Checking turning
direction" on page 79).
During programming, ensure there is no
person or object in the radius of action of the
gate and the operation mechanisms.
D1 and D2:
CL
(static)
Gate closed
CL
(flashing)
Gate closing
OP
(static)
Gate open
OP
(flashing)
Gate opening
PC
(flashing)
Pedestrian door closing
PO
(static)
Pedestrian door open
PO
(flashing)
Pedestrian door opening
XX
(countdown)
Gate on standby
PA
(static)
Pause (operation not complete)
rS
(flashing)
Gate carrying out reset (searching
for close position after
opening operation)
rS
(static)
Gate waiting to carry out reset
D3 and D4:
C4
Opening safety device* activated
C5
Closing safety device* activated
C9
Mechanical or resistive strip activated
E1
Encoder failure motor 1
E2
Encoder failure motor 2
F1
Motor 1 force limit exceeded
F2
Motor 2 force limit exceeded
* : in swing gates, C4 refers to the interior
photocell and C5 to the exterior photocell
(instead
of
respectively).
HP.
Dead man function
StOP
Operator unlocked
CHANGING
TURNING
opening
and
closing,
Control board VIVO-M203(M)
English
77

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vivo-m203m

Table des Matières