Operator connections for single or dual leaf swing gates
(parameter C301)
ST1: open
ST2: close
The G1/G4 and G2/G5 wire colours must be respected in order to correctly programme the turning
directions, i.e. G1 must be the same as G4 (and G2 must be the same as G5).
erator connection
Single encoder
connection (C701)
V+:
red wire
GND: mesh
SGN1: green
or blue
SGN2: do not connect SGN2: close (FCC)
The option C704 is not available for swing gate operators. If C704 is
selected, it will work as C701.
Limit switches
connection (C702)
V+:
do not connect
GND: common (COM)
SGN1: opening (FCA)
A1:
operator 1
A2:
operator 2
Dual encoder
Vulcan Connection
connection (C703)
VUS (C705)
V+:
red wire
V+:
GND: mesh
GND: common (COM)
SGN1: green
SGN1: VUS operator safety
or blue wire
SGN2: white wire
SGN2: electrolock micro (in A1
INSTALLATION
G1/G4: open
G2/G5: close
G3/G6: common
do not connect
micro
connector only)
Control board VIVO-M203(M)