4 OPERATION
CURRENT
ENTER
PULSE

4.3.5 Pulse output

In this menu, the parameters of the pulse output are defined, and the volume corresponding
to one pulse is entered. First enter the unit, then the value.
Example: 1 pulse corresponds to 5 L
PULSE
ENTER

RELAY

The pulse unit is set by the flow unit. Metric unit will be m
- The pulse frequency is given by f = Q / Pu; frequency must never
exceed 250 Hz. Select the Pulse value in order to obtain a maximum
frequency of approx. 200 Hz.
- If the pulse frequency is smaller than 5 Hz, the pulse width will equal
100 ms. For pulse frequencies higher than 5 Hz the duty cyclic is of 50%.
4 = 0000
Entering the beginning of the
0......9
measuring range
4 = 0000
ENTER
ENTER
LITER
M3
0......9
USGAL
IMPGAL
E-25-
8025 UNIVERSAL
20 = 0000
Entering the end of the
measuring range
0......9
20= 0180
ENTER
PU =000.00
0......9
ENTER
PU =005.00
3
or Liter.
Input of the quantity
corresponding to one
pulse