date of manufacture. This
is the responsibility of the
operator.
4. Liquid gas equipment
must not be used when
refuelling, in multi-storey
car parks, in garages or on
ferries.
5. During the initial operation
of a brand new appliance (or
after it has not been used for
some time), a slight amount
of fumes and smell may be
noticed for a short while. It
is a good idea to heat the
device up several times in
summer operation (60°C) and
to make sure that the area is
well ventilated.
6. If the burner makes an
unusual noise or if the flame
lifts off, it is likely that the
regulator is faulty and it is
essential to have it checked.
7. Items sensitive to heat
(e.g. spray cans) must not be
stored in the installation area,
since excess temperatures
may under certain circum-
stances be incurred there.
8. Only pressure control
equipment that complies
with EN 12864 (in vehicles)
and EN ISO 10239 (for boats)
with a fixed delivery pressure
of 30 mbar (or 50 mbar in
older systems) must be used
for the gas system. The flow
rate of the pressure control
device must correspond
to at least the maximum
consumption of all devices
installed by the system
manufacturer.
For vehicles we recommend
the Truma SecuMotion gas
pressure regulator and the
Truma DuoComfort automat-
ic changeover valve for the
two-cylinder system.
At temperatures of around
0°C or less the gas pressure
regulator and the changeover
valve must be operated using
the EisEx de-icing system.
Controller connecting hoses
that meet national regula-
tions must always be used
in the respective country
for which the equipment is
destined. These hoses must
be checked regularly for brit-
tleness. Winter-proof special
hoses must always be used
if the equipment is operated
during the winter.

Technical data

determined in accordance
with EN 624 or Truma test
conditions
Type of gas:
Liquid gas (propane/butane)
Operating pressure:
30 mbar (or 50 mbar in
older systems – refer to
data plate)
Water contents:
12 litres
Heating up time from
approx. 15°C to approx.
60°C:
Boiler approx. 30 minutes
(measured according to
prEN 15033)
Heater + water heater
approx. 80 min.
Water pressure:
max. 2.8 bar
Rated thermal output
C 4002: 2000/4000 W
C 6002: 2000/4000/6000 W
Gas consumption
C 4002: 170 – 320 g/h
C 6002: 170 – 480 g/h
Air delivery volume (free-
blowing without hot-air pipe)
C 4002: with 3 hot-air
outlets
max. 249 m³/h
with 4 hot-air
outlets
max. 287 m³/h
C 6002: with 4 hot-air
outlets
max. 287 m³/h
Current input at 12 V
Heater + water heater
C 4002: 0.2 – 5.6 A
(average power
consumption 1.3 A)
C 6002: 0.2 – 5.6 A
(average power
consumption 1.4 A)
Heating up of water heater:
0.4 A
Stand-by:
0.001 A
Current input of electrical
safety/drain valve at 12 V:
0.035 A
Weight:
17.6 kg
(without water contents)
Declaration of conformity:
The Trumatic C has been
tested by the DVGW and
complies with the gas equip-
ment directive (90/396/EEC)
and the other applicable EC
directives. The following
CE Product Ident. No. is
available for EU countries
C 4002: CE-0085AS0121
C 6002: CE-0085AS0122.
The heater complies with
heating equipment directive
2001/56/EC with supplement
2004/78/EC.
The heater complies with
the vehicle engine interfer-
ence suppression directive
72/245/EEC with supplements
2004/104/EC and 2005/83/EC.
The heater complies with
EMC directive 89/336/EEC
and low voltage directive
73/23/EEC.
The right to effect technical
modifications is reserved!
11