Overheating protection 230 V
230 V
heating mode has a mechanical overheating protec-
tion switch. If the 12 V
power supply is interrupted, for
example during operation or during the after-run period, the
temperatures within the appliance could activate the over-
heating protection.
Figure 7
Resetting the overheating protection: Allow the heater to cool,
remove the connection cover and press the reset button
.

Technical data

Determined in accordance with EN 624 or Truma test
conditions
Gas type
Liquefied gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Water capacity
10 litres
Heating time from approx. 15 °C to approx. 60 °C
Boiler approx. 23 minutes (measured according to EN 15033)
Heater + boiler approx. 80 Min.
Pump pressure
max. 2.8 bar (280 kPa)
System pressure
max. 4.5 bar (450 kPa)
Rated heat output (automatic operating levels)
Gas mode
Combi 2 E UK:
2000 W
Combi 4 (E) / 4 E UK: 2000 W / 4000 W
Combi 6 (E) / 6 E UK: 2000 W / 4000 W / 6000 W
Electric mode
Combi 2 E UK / 4 E (UK) / 6 E (UK): 900 W / 1800 W
Mixed mode (gas and electric)
Combi 2 E UK /
Combi 4 E (UK): max. 3800 W
Combi 6 E (UK): max. 5800 W
Gas consumption
Combi 2 E UK:
160 g/h
Combi 4 (E) / 4 E UK: 160 – 335 g/h
Combi 6 (E) / 6 E UK: 160 – 460 g/h
Standby heat requirement (all appliances)
Gas mode 5.2 g/h
Additional information according to EN 624
Combi 2 E UK:
Q
= 2.4 kW (Hs), 170 g/h, C
n
Combi 4 (E) / 4 E UK: Q
= 4.8 kW (Hs), 345 g/h, C
n
Combi 6 (E) / 6 E UK: Q
= 6.8 kW (Hs), 480 g/h, C
n
Destination countries
Combi 2 E UK: GB, IE
Combi 4 (E) / 4 E UK / 6 (E) / 6 E UK:
DE, AT, CH, DK, FI, NL, NO, SE, SK, CH, CZ, CY, BE, IT, RO,
GR, LI, LU, IS, PL, EE, LT, LV, MC, MT, PT, SI, HR, HU, FR, BG,
SM, TR, GB, IE
Air flow rate (free-blowing without warm air duct)
Combi 2 E UK / Combi 4 (E) / 4 E UK:
with 3 warm air outlets max. 249 m³/h
with 4 warm air outlets max. 287 m³/h
Combi 6 (E) / 6 E UK:
with 4 warm air outlets max. 287 m³/h
(Combi E)
Power consumption at 12 V
Heater + boiler
Combi 2 E UK /
Combi 4 (E) / 4 E UK: 1.2 – 6.5 A
Combi 6 (E) / 6 E UK: 1.4 – 6.5 A
Boiler heating maximum 0.5 A
Quiescent current approx. 0.001 A
Heating element – FrostControl (optional): maximum 0.4 A
Power consumption at 230 V
Combi 2 E UK / Combi 4 E (UK) / Combi 6 E (UK)
3.9 A (900 W) or 7.8 A (1800 W)
Protection class
IP 21
Weight
(without water)
Heater:
Heater with periphery:
Subject to technical changes.

Dimensions

Figure 8
Subject to technical changes.

Disposal

The appliance must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-Life Vehicle Regulation) must be observed.
, I
13
3 B/P(30)
, I
13
3 B/P(30)
, I
13
3 B/P(30)
Combi 2 E UK
Combi 4 E (UK)
Combi 6 E (UK)
15.5 kg
16.0 kg
0085
450 mm
Combi 4
Combi 6
14.4 kg
14.9 kg
510 mm
EN
21

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Combi 4Combi 4 eCombi 4 e ukCombi 6Combi 6 eCombi 6 e uk ... Afficher tout

Table des Matières