MAINTENANCE
l Plug the wall receptacle end of the battery charger into a 120
Volt AC wall outlet.
BATTERY REPLACEMENT
See Figure 41.
CAUTION
and lead compounds. Wash hands after handling.
l Remove the wheel in front of the battery.
l Remove the two bolts and battery plate. Tilt the battery forward
and remove.
l Disconnect the negative (–) cable (black boot) from the negative
(–) battery post.
l Disconnect the positive (+) battery cable (red boot) from the
positive (+) battery post.
NOTICE
Always connect the cables in the following
sequence to avoid possible shock.
l On the replacement battery, connect the positive (+) battery
cable (red boot) to the battery positive (+) terminal. Secure the
boot over the battery post.
l Connect the negative (–) battery cable (black boot) to the negative
(–) positive terminal. Secure the boot over the battery post.
l Install the battery in the battery tray. Install the battery plate
and bolts. Tighten the bolts securely.
NOTICE
Dispose of the used battery properly ac-
cording to the guidelines established by the local or state
government.
l Reinstall the wheel.