OPERATION
l Press and hold the engine start/stop button for 10 seconds until
the LED around the button flashes green, then release it.
l Press and hold the start button on the key fob for one second,
then release it.
• If the key fob paired successfully, the LED around the engine
start/stop button will turn solid green.
• If pairing was unsuccessful, the LED around the engine start/
stop button will continue flashing green. Wait several seconds,
then make a second attempt. If the second attempt fails, turn
the battery switch to the OFF position, wait several seconds
and repeat the process. If subsequent attempts fail, turn the
battery switch to the OFF position and contact customer
service.
l After the key fob is successfully paired to the generator, turn
the battery switch to the OFF position.
BREAK-IN PERIOD
For proper break-in, do not exceed 50% of the rated running watts
during the first five hours of operation.
Use supplied oil until first recommend oil change. Do not use full
synthetic oil during break in period. Full synthetic oil may prevent
proper breaking and seating of the piston rings.
Vary the load occasionally to allow stator windings to heat and
cool and help seat the piston rings.
BEFORE STARTING THE GENERATOR
Confirm that:
l The generator is placed in a safe, appropriate location.
l The generator is on a dry, flat, and level surface.
l Oil and fuel levels are within safe operating range.
l All loads are disconnected from the control panel receptacles.
DANGER
move or tip the generator during operation.
STARTING THE GENERATOR
See Figures 24 - 27.
l Place the generator in a safe, appropriate location.
l Unplug all loads.
l Inspect oil and fuel levels. If needed add oil, refill the LP gas
cylinder, add gasoline, or contact the natural gas utility company.
l Using the fuel selector switch, select GASOLINE, PROPANE
NATURAL GAS.
or
l Start the flow of desired fuel and stop the flow from other fuel
sources.
• For gasoline, open the fuel valve and turn off the flow of natural
or propane gas.
• For propane, open the cylinder valve on the LP gas cylinder
and turn off the flow of natural gas and gasoline.
• For natural gas, open the valve on the natural gas supply line
and turn off the flow of propane gas and gasoline.
l Push the battery switch to the ON position.
24 | English
Fire and explosion hazard. DO NOT
FIG. 22
A
C
A - Voltage
B - Frequency
C - Lifetime hours
D - Run time/maintenance reminder
E - Mode button
FIG. 23
D
A - Red LED
B - Start button
C - Stop button
D - Key fob
FIG. 24
A
,
A - Fuel selector switch
B - Engine start/stop button
C - Battery indicator
D - Battery switch
E
A
B
START
C
STOP
B
C
B
D
D

Publicité