MAINTENANCE
BATTERY MAINTENANCE
See Figure 40.
WARNING
drogen gas during normal operation. A spark or flame can
cause the battery to explode with enough force to kill or
cause serious injury. Wear protective clothing and a face
shield, or have a skilled technician perform battery main-
tenance.
WARNING
sulfuric acid (electrolyte) which is highly corrosive and poi-
sonous. Wear protective clothing and eye protection when
working near the battery. Keep children away from the bat-
tery.
WARNING
or other sources of ignition. NEVER touch both battery ter-
minals at the same time with any body part or any non-in-
sulated tools. If battery acid contacts skin or clothing, flush
immediately with water and neutralize with baking soda.
The battery shipped with the generator has been fully charged.
A battery may lose some charge when not in use for prolonged
periods of time.
NOTE: Once started, the generator will charge the battery after
30 – 60 minutes of use.
When the generator is not running, the included trickle charger can
remain connected and will maintain the battery for an indefinite
period of time. A red light on the charger indicates charging in
progress. A green light indicates charging complete. Charge in a
dry location.
l Plug the charger into the battery charging port on the control
panel.
32 | English
The battery gives off explosive hy-
Burn hazard. The battery contains
NEVER smoke or work near sparks
FIG. 38
A
B
A - Gasket
B - Rocker arm cover
C - Bolt
FIG. 39
A
A - Valve stem
B - Rocker arm
C - Pivot adjusting nut
D - Rocker arm pivot
B