OPERATION
WARNING
a leak test any time the natural gas hose is disconnected and
reconnected.
l Turn the generator off and allow the engine to cool for at least
five minutes.
l Confirm that the gas is turned off at the natural gas supply line.
l Completely unwrap and straighten the natural gas hose (not
included) to prevent kinks.
l Use your hand to thread the hose to the natural gas supply line.
Do not cross-thread. Do not use tools or sealants.
l Attach the quick connect adapter (not included) to the generator
and tighten securely.
l Connect the natural gas hose to the generator using the
quick-connect collar.
• Pull back the quick-connect collar.
• Push the hose onto the natural gas/propane inlet.
• Push the collar forward so that the hose is secured properly.
Gently pull the hose to see that it is secure.
NOTE: The natural gas hose and quick connect adapter must be
ordered separately. To order, please go to parts.wpowereq.com.
SELECTING THE FUEL SOURCE
See Figure 20 - 21.
DANGER
add gasoline to the fuel tank or connect the LPG/propane
hose or natural gas hose to the generator while the genera-
tor is in operation.
NOTICE
Do not overload the generator. Load capac-
ities differ depending on the fuel source. Before switching
fuel sources, be sure the generator can supply enough run-
ning (continuous) and peak (starting) watts for the connect-
ed items.
22 | English
To reduce the risk of injury, perform
Fire and explosion hazard. DO NOT
FIG. 18
A
A - Natural gas/propane inlet
B - Natural gas hose (not included)
C - Pull collar back
D - Push hose onto inlet
E - Push collar forward
FIG. 19
A
A - Natural gas hose (not included)
B - Natural gas supply line
C
D
E
B