OPERATION
l Disconnect the propane hose from the LP gas cylinder and the
generator or disconnect the natural gas hose from the natural
gas supply line and the generator.
To stop the unit quickly in an emergency:
l Press and hold the engine START/STOP button or the stop
button on the key fob for one second to stop the generator.
CIRCUIT BREAKERS
See Figures 28 - 29.
The 20 amp circuit breaker protects devices and equipment con-
nected to the 120V, 20 amp receptacles from electrical overload.
The 30 amp circuit breaker protects devices and equipment
connected to the 120V, 30 amp receptacles. The main circuit
breaker will automatically switch OFF if the combined load of the
receptacles exceeds the capacity. If a circuit breaker activates,
turn off the connected device, remove it from the port or outlet,
and reset the circuit breaker.
USB PORTS
See Figure 29.
Use the USB ports and USB cables (not included) to charge
USB-compatible devices such as phones, tablets, and speakers
(up to 2.1 Amps).
NOTE: The USB ports are designed for charging only and do not
have data transfer or communication capabilities.
TRANSPORTING
l Turn off the generator.
l Allow the generator to cool a minimum of 30 minutes before
transporting.
l Replace all protective covers on the generator control panel.
l Always use the frame, not the handle, to lift the unit or attach
any load restraints such as ropes or tie-down straps. DO NOT
attempt to lift or secure the generator by holding onto any of
its other components.
l Keep the unit level during transport to minimize the possibility
of fuel leakage or, if possible, drain the fuel or run the engine
until the fuel tank is empty before transport.
CAUTION
erator or place it on its side. Fuel or oil can leak and damage
to the generator may occur.
26 | English
Fire hazard. DO NOT up-end the gen-
FIG. 28
A
C
A - 120/240 volt AC 30 amp receptacle
B - 120 volt AC 20 amp GFCI receptacles
C - 30 amp circuit breaker
D - 20 amp circuit breakers
FIG. 29
A
A - Main circuit breaker
B - USB ports
C - 120/240 volt AC 50 amp receptacle
B
D
D
B
C