OPERATION
NOTICE
Do not overload the generator. Load capac-
ities differ depending on the fuel source. Before switching
fuel sources, be sure the generator can supply enough run-
ning (continuous) and peak (starting) watts for the connect-
ed items.
The fuel source can be switched while the engine is off or while it
is running if a propane tank or natural gas supply line is connected
to the generator BEFORE operation. If switching from gasoline to
another fuel source while the engine is running, it may run rough
for a few seconds as it purges gasoline from the carburetor.
To switch to gasoline:
l Turn the fuel valve to the open position to start the flow of
gasoline.
l Rotate the fuel selector switch to Gasoline.
l Turn off the flow of natural or propane gas.
To switch to propane:
l Open the cylinder valve on the LP gas cylinder to start the flow
of propane.
l Rotate the fuel selector switch to Propane.
l Turn off the flow of natural gas and gasoline.
To switch to natural gas:
l Open the valve on the natural gas supply line to start the flow
of natural gas.
l Rotate the fuel selector switch to Natural Gas.
l Turn off the flow of propane and gasoline.
HIGH ALTITUDE OPERATION
Engine power is reduced the higher it is operated above sea level.
Output will be reduced approximately 3.5% for every 1000 feet of
increased altitude from sea level.
High altitude adjustment is required for operation at altitudes
over 5,000 ft. (1524 m). Operation without this adjustment will
cause decreased performance, increased fuel consumption, and
increased emissions.
NOTICE
DO NOT operate the generator at altitudes
below 2,000 ft. (762 m) with the high altitude kit installed.
Engine damage may occur.
High Altitude
Carburetor Kit
DATA CENTER
See Figure 22.
Push the mode button to cycle through the data display modes.
Voltage: Displays current voltage output.
Frequency (Hz): Displays power output frequency in Hertz.
Lifetime Hours: Displays the lifetime run hours.
Run Time/Maintenance: Displays current run time. Resets
to zero when shut down. Maintenance reminder displayed when
required.
Part# 518563
FIG. 20
B
A
A - Fuel valve (open)
B - Fuel valve (close)
FIG. 21
E
A
A - Fuel off
B - Natural gas
C - Propane
D - Gasoline
E - Fuel selector switch
Maintenance Codes:
P25 – Change engine oil
P50 – Clean air filter, Change engine oil
P100 – Change engine oil, clean air filter, replace fuel filter
PAIRING THE KEY FOB
See Figures 23 - 24.
l Bring the key fob in range of the generator.
l Ensure the battery is connected and the fuel selector switch is
in the FUEL OFF position .
l Push the battery switch to the ON position.
NOTE: When battery power is available, the battery indicator
light will illuminate and the LED around the engine start/stop
button will illuminate solid green.
B
D
English | 23
C