Installation Instructions
Installation Precautions
· If the size of the 3-way diverter valve does not match, please purchase
a suitable adapter separately.
· Use a water pressure gauge to measure the water pressure and
confirm that it is between 0.14 MPa and 0.8 MPa.
· Close the main water valve in your home before installation and make
sure all the water in the pipes has been drained.
· Do not connect the base station to a hot water source.
· Before installation, please unplug the base station and make sure the
base station is not connected to the power supply.
Installation Precautions
· Installation location needs to avoid direct sunlight and water.
· The location is recommended to be close to the water source and floor
drain.
· It is recommended that the distance between the base station and the
socket be within 1.5 m.
· Remove any objects that are closer than 60 cm from the front of the
base station.
· Place the base station in a location with a good 2.4 GHz Wi-Fi signal.
19
0.14-0.8 MPa
Water Source
Socket
Floor
Drain
Installation Instructions
Completed Installation
Power Cord
3-Way Diverter Valve
1/4" Clean
Water Pipe
Spiral Cable
Wrap
Floor Drain
3/8" Used
Water Pipe
Note:
·
The illustrations in this manual are for reference only. Please refer to the actual installation
situation.
·
It is recommended that the installation height of the used water pipe should not be higher
than 80 cm.
EN
How to install Connection Locking Clip
Adjust the direction of the handle on the
connection locking clip to be consistent
with the illustration, and then press the
clip downward along the gap as shown
in the illustration.
Handle
Note: Before installing, make sure that all
connecting accessories are firmly installed.