Technical Data
Max. lift capacity*
Weight (without suction plate)
Vacuum reservoir volume
Vacuum pump suction capacity
Switch setting 1 (1 pump running)
Switch setting 2 (2 pumps running)
Max. final pressure
Operating temperature range
Voltage
Current consumption
Switch setting 1 (1 pump running)
Switch setting 2 (2 pumps running)
Medium to be pumped
* The maximal load capacity of the lifting device depends on the suction plate (not
included in delivery, see section 5.3)
DANGER
Technical data of the remote control
(only for SM-600-POWER-FFS)
Frequency band
Amount of Channels
IP code
Operating temperature
22/44
Risk of injury from exceeding capacity load
The permissible load capacity of the transportation or lifting device (e.g.
crane, chain hoist, construction vehicle, etc.) and the hoist must be high
enough at least to be equal to the combined weight and load capacity of
the lifting device.
Standard
SM-600
SM-600-POWER /-POWER-FFS
600 kg
Approx. 34 kg
approx. 2.5 l
29 l/min
58 l/min
500 mbar vacuum
+3 °C to 40 °C
DC 12 V
3.8 A
7.6 A
Ambient air
Power
SM-600-POWER-FFS
2405-2480 MHz
16 (channel 11-26)
-20 – +55 °C / -4 – +130 °F
Power
Approx. 35 kg
52 l/min
104 l/min
4.5 A
9.0 A