To call up and to set functions of the pump:
Main menu:
To Call up the main menu when the pump is in operation:
v Push the centre and right buttons simultaneously until the main menu
is shown in the display.
To Call up the main menu when the pump is switched off:
v Push and hold the centre and right buttons simultaneously and
switch on the pump until the main menu is shown in the display.
As long as the main menu or a submenu is called up, the pump
stops operation for safety reasons.
2.1 Overview
Display of:
– Total delivery capacity
– Partial delivery capacity
– Turn on pressure
– Leakage warning
– Diagnosis system
– Pump temperature
2.2 Reset
Reset of:
- Partial delivery capacity to 0
- Min./max. Pump temperature
2.3 Main menu
Leads back to the main menu.
GAR_01759-20.960.11_2024-01-30.indd 13
GAR_01759-20.960.11_2024-01-30.indd 13
The main menu has 4 menus:
1. Language
2. Info menu
3. Settings
4. Exit
v Select the desired menu with the left
or right button and call it up with the
centre button.
1. Language
The display language can be selected in
the "Language" menu.
v Select the desired display language with
the left or right button and confirm with
the centre button.
2. Info menu
The "Info Menu" menu has 3 submenus:
2.1 Overview
2.2 Reset
2.3 Main menu
v Select the desired menu with the left
or right button and call it up with the
centre button.
3. Settings
The "Settings" menu has 5 submenus:
3.1 Leakage warning
3.2 Turn on pressure
3.3 Troubleshooting
3.4 Factory settings
3.3 Main menu
v Select the desired menu with the left
or right button and call it up with the
centre button.
3.1 Leakage warning
To set the duration until the leakage
warning is activated:
– ON (60 min)
– ON (2 min)
– OFF
v Select the desired duration with the left
or right button and confirm it with the
centre button.
3.2 Turn on pressure
The turn-on pressure is set to the maximum value at the factory and can
be reduced to 2.0 bar in 0.2 bar steps.
To set the turn-on pressure:
v Select the desired turn-on pressure with the left or right button and
confirm it with the centre button.
3.3 Troubleshooting
To activate troubleshooting.
– ON:
Shows the most frequent causes and their remedy on the
display.
– OFF: Only the error code is shown on the display.
v Select the desired setting with the left or right button and confirm it
with the centre button.
3.4 Factory settings
Reset to the factory settings of:
– Leakage warning to 60 min.
– Turn on pressure to maximum value
– Troubleshooting to ON
3.5 Main menu
Leads back to the main menu.
4. Exit
Closes the main menu.
The pump is ready for operation again.
5. MAINTENANCE
DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect the product from the mains before you maintain
the product.
To clean the filter [ Fig. M1 / M2 ]:
1. If applicable, close all the shutoff devices on the intake side.
2. Loosen the lid
of the filter chamber with the spanner
9
3. Remove the filter unit
/
vertically upwards.
w
e
4. Hold the cup
firmly, turn the filter
w
remove the filter 2 (bayonet fitting).
5. Clean the cup
under running water and clean the filter
w
e. g. with a soft brush.
6. Assemble the filter again in reverse order.
7. Start the pump (see 3. OPERATION).
To clean the check valve [ Fig. M3 ]:
CAUTION!
The pump must not be operated without the check valve.
1. If applicable, close all the shut-off devices on the intake side.
2. Open all tapping points so that the pressure escapes on the pressure
side. Now close the tapping points again so that the connected pipes
do not drain via the pump.
3. Loosen the cover
of the check valve with a suitable tool.
r
4. Remove the check valve
and clean it under running water.
t
5. Assemble the check valve
again in reverse order.
t
6. Start the pump (see 3. OPERATION).
6. STORAGE
To put into storage [ Fig. S1 ]:
The product must be stored away from children.
to position 0.
1. Push the on / off switch
q
2. Disconnect the pump from the mains.
provided.
>