*Channel LEDs will flicker when variable information for the particular
channel has been updated. Even if a sample rate has been specified,
updates may occur more frequently if other devices on the
communication bus (e.g. a remote meter) request the same variable
information from a Morningstar Device. Flickering channel LEDs allow
the user to visually verify that variable information is being received.
Fault Indications
Red Solid (Power LED Only): Firmware update failed. Retry the
firmware update.
Red/Green Flash (Power LED Only): Temperature sensor fault or
factory calibration problem. Return for service.
Red Flash (Channel LED Only): Channel Fault/Alarm. Indicates a
channel short circuit or over-current condition.
Red Flash (All LEDs): Configuration Update – reset needed to resume
operation with new settings. This indication occurs each time a new
configuration is programmed into the Relay Driver.