High Threshold during the delay time, the counter will be
reset. (See Figure 6)
Max High Time – maximum amount of time the Relay Driver
will remain in the High state. This timer begins after the Min.
High timer has expired.
Min. High Time – minimum amount of time the Relay Driver
must remain in the High state.
Low Threshold – lower value at which an event should occur
High to Low Delay –time to wait after Low Threshold is met
before changing state. If the Control Variable rises above Low
Threshold during the delay time, the counter will be reset.
(See Figure 6)
Max Low Time – the maximum amount of time the Relay
Driver will remain in the Low state. This timer begins after the
Min. Low timer has expired.
Min. Low Time – minimum amount of time the Relay Driver
must remain in the Low state
Sample Period – how frequently the Control Variable value is
updated. (Not applicable in standalone)
Timeout – period of time to wait before a communications
timeout is declared.