3.2 Assign Functions
Each of the four channels is assigned a Function, which switches
channel(s) on/off based on criteria. Some Functions only control one
channel while others manage two or more channels as a group.
The Relay Driver Setup screen, shown in Figure 3 is the starting point
from which each channel is setup. The upper left area of the window
displays the four channels and the corresponding configurations.
Each of the four (4) channels has a configuration summary that shows
which Function is assigned as well as a few key parameters.
Next to each channel Configuration Summary are two setup buttons
labeled Simple and Advanced. Simple setup allows the user to modify
the most essential settings while using factory default values for the
more advanced settings. Advanced setup allows the user to specify all
parameters including control address, sample rate, defaults states, and
more.
NOTE: Simple setup is recommended unless there is a
specific need to modify an Advanced parameter.
The four buttons located in the bottom right corner are defined as
follows:
Write to File - allows the user to save a configuration for later use.
Read from File - retrieve past configurations saved to file
Read Module – read the current configuration out of the Relay Driver.
Program module - write the wizard configuration to the Relay Driver
RELAY DRIVER
10 |
P a g e

Publicité